Basic data | Series: 96 Operating principle: Diffuse reflection principle with background suppression |
Optical data | Operating range: Guaranteed operating range Operating range, white 90%: 0.1 ... 1.2 m Operating range, gray 18%: 0.1 ... 1.1 m Operating range, black 6%: 0.1 ... 1 m Operating range limit: Typical operating range Operating range limit, white 90%: 0.1 ... 1.8 m Operating range limit, gray 18%: 0.1 ... 1.6 m Operating range limit, black 6%: 0.1 ... 1.35 m Light source: LED, Infrared |
Electrical data | Performance data Supply voltage UB: 20 ... 230 V, AC/DC Residual ripple: 0 ... 15 %, From UB Outputs Number of digital switching outputs: 1 Piece(s) Switching output 1: Array |
Time behavior | Switching frequency: 20 Hz |
Connection | Connection 1 Type of connection: Terminal No. of pins: 5 -pin |
Mechanical data | Dimension (W x H x L): 30 mm x 90 mm x 70 mm Housing material: Metal Metal housing: Zinc Lens cover material: Glass Net weight: 380 g Compatibility of materials: ECOLAB Note: Housing part used contains perfluorobutanesulfonic acid (PFBS) |
Operation and display | Type of display: LED Operational controls: Multiturn potentiometer |
Environmental data | Ambient temperature, operation: -40 ... 55 °C |
Certifications | Degree of protection: IP 67 Protection class: II Certifications: c UL US Standards applied: IEC 60947-5-2 |