Industrial Automation
Basic data | Series: 96 Type of scanning system: Against object |
Optical data | Light source: Laser, Red Laser class: 2, IEC/EN 60825-1:2014 Light spot size [at sensor distance]: 7 mm x 7 mm [10,000 mm] |
Measurement data | Measurement range: 300 ... 10,000 mm Resolution: 3.0 mm Accuracy: 0.5 % Reference value, accuracy: End value Repeatability: 5 mm Measurement time: 1.4 ... 50 ms Referencing: No Optical distance measurement principle: Time of flight |
Electrical data | Performance data Supply voltage UB: 10 ... 30 V, DC Outputs Number of digital switching outputs: 1 Piece(s) Switching output 1: Array |
Interface | Type: RS 485 |
Connection | Connection 1 Type of connection: Connector Thread size: M12 Material: Metal No. of pins: 5 -pin |
Mechanical data | Dimension (W x H x L): 30 mm x 90 mm x 70 mm Housing material: Metal Metal housing: Diecast zinc Lens cover material: Glass Net weight: 380 g |
Operation and display | Type of configuration: Software Operational controls: Membrane keyboard PC software |
Environmental data | Ambient temperature, operation: -20 ... 50 °C Ambient temperature, storage: -30 ... 70 °C |
Certifications | Degree of protection: IP 67 IP 69K Protection class: II Certifications: c UL US Standards applied: IEC 60947-5-2 |