Industrial Automation
Basic data | Series: 18B Operating principle: Reflection principle Application: Detection of highly transparent bottles Detection of highly transparent films and glass panes |
Special version | Special version: Autocollimation |
Optical data | Operating range: Guaranteed operating range Operating range limit: 0 ... 4.8 m Light source: LED, Red Wavelength: 620 nm LED group: 1 |
Electrical data | Protective circuit: Polarity reversal protection Short circuit protected Performance data Supply voltage UB: 10 ... 30 V, DC Residual ripple: 0 ... 15 %, From UB Open-circuit current: 0 ... 18 mA Outputs Number of digital switching outputs: 2 Piece(s) Switching output 1: Array Switching output 2: Array |
Time behavior | Switching frequency: 1,500 Hz Response time: 0.333 ms Readiness delay: 300 ms |
Connection | Connection 1 Function: Signal OUT Voltage supply Type of connection: Connector Thread size: M12 Type: Male Material: Metal No. of pins: 4 -pin Encoding: A-coded |
Mechanical data | Dimension (W x H x L): 15 mm x 47 mm x 32.5 mm Housing material: Metal Metal housing: Diecast zinc Lens cover material: Glass Net weight: 60 g Housing color: Silver Type of fastening: Front mounting with thread Through-hole mounting Via optional mounting device Compatibility of materials: ECOLAB |
Operation and display | Type of display: LED Operational controls: Multiturn potentiometer |
Environmental data | Ambient temperature, operation: -40 ... 60 °C Ambient temperature, storage: -40 ... 70 °C |
Certifications | Degree of protection: IP 67 IP 69K Protection class: III Certifications: c UL US Standards applied: IEC 60947-5-2 |
Description other products