Technical Specs
Basic dataSeries: MSI-SR-LC21
Application: E-Stop circuits
Optoelectronic protective devices
Position switches (mechanical contacts)
Solenoid switches (reed contacts, equivalent)
Transponder switches (OSSD outputs)
FunctionsFunctions: Contactor monitoring (EDM)
Start/restart interlock (RES)
Restart: Automatic
Manual
Characteristic parametersSIL: 3, IEC 61508
SILCL: 3, IEC/EN 62061
Performance Level (PL): e, EN ISO 13849-1
MTTFd: 78 years, EN ISO 13849-1
PFHD: 1,7E-09 per hour
Mission time: 20 years, EN ISO 13849-1
Category: 4, EN ISO 13849-1
DCAVG: 99 %
B10d at DC13 (inductive load): 435,000 number of cycles, (2.5 A, 230 V), 700,000 (1 A, 230 V)
B10d at AC15 (inductive load): 230,000 number of cycles, (3 A, 230 V), 380,000 (1 A, 230 V)
Electrical dataContinuous current per current path, max.: 6 A
Performance data
Supply voltage UB: 24 V, AC/DC, -15 ... 10 %
Power consumption, max.: 2 W, For 24 V, plus output load
Supply circuit
Nominal voltage UN: 24 V
Nominal frequency: 50 ... 60 Hz
Operating voltage: 0.85 ... 1.1 x UN
Rated power DC: 2 W
Galvanic isolation between supply and control circuit: No
Output circuit
Number of outputs, safety-oriented, undelayed, contact-based: 2 Piece(s)
Number of outputs, safety-oriented, delayed, contact-based: 0 Piece(s)
Number of outputs, signaling function, undelayed, contact-based: 1 Piece(s)
Release current paths: NO
Signaling current paths: NC
Contact material: Ag alloy, gold-plated
Usage category AC-15 (NO contact): Ue 230V, Ie 3A
Usage category DC-13 (NO contact): Ue 24V, Ie 2,5A
Short circuit protection (NO contact): gG class safety fuse 6A, melting integral
Max. thermal continuous current Ith, release current paths: 6 A
Max. thermal continuous current Ith, signaling current paths: 3 A
Max. total current I² of all current paths: 9 A²
Mechanical life time: 100,000,000 switching cycles
Control circuit
Evaluation of the inputs: Two-channel
Input current at the control inputs (safety circuit/reset circuit): 40 mA
Max. peak current at the control inputs (safety circuit/reset circuit): 100 mA
Max. cable resistance, per channel: ≤ (5 + (1.176 x UB / UN - 1) x 100) Ω
Minimum switch-on time: 50 ms
Response time (automatic start tA2): 500 ms
Response time (manual start tA1): 40 ms
Test pulse time permitted tTP: 1 ms
Release time tR: 25 ms
Sychronous time monitoring tS: 200 ms
Recovery time tW: 150 ms
Time behaviorRegression delay: 25 ms
ConnectionNumber of connections: 1 Piece(s)
Connection 1
Function: Signal IN
Signal OUT
Voltage supply
Type of connection: Terminal
Type of terminal: Spring-cage terminal
No. of pins: 16 -pin
Cable properties
Connection cross sections: 2 x 0.2 to 1.5 mm², wire
2 x 0.25 to 1.5 mm², wire with wire-end sleeve
Mechanical dataDimension (W x H x L): 22.5 mm x 106.5 mm x 114 mm
Net weight: 210 g
Housing color: Gray
Type of fastening: Snap-on mounting
Environmental dataAmbient temperature, operation: -25 ... 55 °C
CertificationsCertifications: TÜV Rheinland
c UL US