Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

LEUZE 50133521
LEUZE 50133521
LEUZE 50133521
LEUZENot available

ISS 244PP.1/44-40N-S12

Inductive switch
Product Code: 50133521
Partner cod.: 50133521
LEUZE


Diminuisci la quantità
Aumenta la quantità
Technical Specs
Technical Specs
Basic dataSeries: 244
Typ. operating range limit Sn: 40 mm
Operating range Sa: 0 ... 32.4 mm
Special versionSpecial version: Antivalent
Electrical dataProtective circuit: Inductive protection
Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC
Residual ripple: 0 ... 20 %, From UB
Open-circuit current: 0 ... 30 mA
Temperature drift, max. (in % of Sr): 10 %, Over the entire operating temperature range
Repeatability, max. (in % of Sr): 10 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C
Switching hysteresis: 15 %
Outputs
Number of digital switching outputs: 2 Piece(s)
Switching outputs: Array
Switching output 1: Array
Switching output 2: Array
Time behaviorSwitching frequency: 100 Hz
Readiness delay: 100 ms
ConnectionNumber of connections: 1 Piece(s)
Connection 1
Function: Signal OUT
Voltage supply
Type of connection: Connector
Thread size: M12
Type: Male
Material: Metal
No. of pins: 4 -pin
Encoding: A-coded
Mechanical dataDesign: Cubic
Dimension (W x H x L): 40 mm x 40 mm x 67 mm
Type of installation: Non-embedded
Housing material: Plastic
Plastic housing: PA 66
Sensing face material: Plastic, Polyamide (PA 66)
Net weight: 130 g
Housing color: Black
Red, RAL 3000
Type of fastening: Through-hole mounting
Standard measuring plate: 120 x 120 mm², Fe360
Operation and displayType of display: LED
Number of LEDs: 4 Piece(s)
Environmental dataAmbient temperature, operation: -25 ... 85 °C
Ambient temperature, storage: -25 ... 85 °C
CertificationsDegree of protection: IP 68
IP 69K
Protection class: II
Certifications: c UL US
Test procedure for EMC in accordance with standard: IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
Standards applied: IEC 60947-5-2
Correction factorsAluminum: 0.2
Stainless steel: 0.85
Copper: 0.1
Brass: 0.25
Fe360 steel: 1