Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

LEUZE 50135419
LEUZE 50135419
LEUZENot available

LSSR 55,300-S12 Ex

Throughbeam photoelectric sensor transmitter
Product Code: 50135419
Partner cod.: 50135419
LEUZE


Diminuisci la quantità
Aumenta la quantità
Technical Specs
Technical Specs
Basic dataSeries: 55
Operating principle: Throughbeam principle
Device type: Transmitter
Special versionSpecial version: Activation input
All stainless steel housing
Optical dataOperating range: Guaranteed operating range
Operating range limit: 0 ... 10 m
Beam path: Divergent
Light source: LED, Red
Wavelength: 620 nm
LED group: 1
Type of light spot geometry: Round
Electrical dataProtective circuit: Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC
Residual ripple: 0 ... 15 %, From UB
Open-circuit current: 0 ... 14 mA
Time behaviorReadiness delay: 300 ms
ConnectionConnection 1
Function: Signal IN
Voltage supply
Type of connection: Cable with connector
Cable length: 300 mm
Sheathing material: PUR
Cable color: Black
Wire cross section: 0.2 mm²
Thread size: M12
Type: Male
Material: Stainless steel
No. of pins: 4 -pin
Encoding: A-coded
Mechanical dataDimension (W x H x L): 19.1 mm x 66 mm x 37 mm
Housing material: Stainless steel
Stainless steel housing: AISI 316L
Lens cover material: Plastic with scratch-resistant Indium protective coating
Net weight: 60 g
Housing color: Silver
Type of fastening: Through-hole mounting
Via optional mounting device
Operation and displayType of display: LED
Environmental dataAmbient temperature, operation: -30 ... 60 °C
Ambient temperature, storage: -30 ... 60 °C
Ex specificationEx device category: 3
Ex device group: II
Ex-SpezifikationEx-Zone: 2
22
CertificationsDegree of protection: IP 67
IP 69K
Protection class: III
Standards applied: IEC 60947-5-2