PHOENIX CONTACT 0717050
PHOENIX CONTACTNot available

HDFK 10-VP/Z - Panel feed-through terminal block

Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Solder connection, number of positions: 1, load current: 57 A, cross section: 0.5 mm2-16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm
Product Code: 0717050
Partner cod.: 0717050
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Panel feed-through terminal block
Product family: HDFK 10-VP
Number of positions: 1
Pitch: 10.1 mm
Number of connections: 2
Number of rows: 1
Number of potentials: 1
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesNominal current IN: 57 A
Nominal voltage UN: 400 V (With metal panels of 1 mm ... 2.5 mm)
Degree of pollution: 3
Rated voltage (III/3): 400 V
Rated surge voltage (III/3): 6 kV
Rated voltage (III/2): 500 V
Rated surge voltage (III/2): 6 kV
Rated voltage (II/2): 1000 V
Rated surge voltage (II/2): 6 kV
Connection dataConnection technology
Connector system: HDFK 10
Nominal cross section: 10 mm²
Conductor connection exterior
Connection method: Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction: 0°
Conductor cross section rigid: 0.5 mm² ... 16 mm²
Conductor cross section flexible: 0.5 mm² ... 10 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 10 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 10 mm²
2 conductors with same cross section, solid: 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible: 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 0.5 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 6 mm²
Internal cylindrical gage: B6
Stripping length: 11 mm
Tightening torque: 1.5 Nm ... 1.8 Nm
Conductor connection interior
Connection method: Solder connection
Connection direction of the conductor to plug-in direction: 0°
Material specificationsMaterial data - contact
Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material: Cu alloy
Surface characteristics: tin-plated
Material data - housing
Color (Housing): gray (7042)
Insulating material: PA
Insulating material group: I
CTI according to IEC 60112: 600
Flammability rating according to UL 94: V0
Glow wire flammability index GWFI according to EN60695-2-12: 850
Glow wire ignition temperature GWIT according to EN60695-2-13: 775
Temperature for the ball pressure test according to EN60695-10-2: 125°C
NotesNotes on safety: The cable entry funnel is not touch-proof. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch proofness.
Safety note
Safety note: • Only electrically qualified personnel may install and operate the product.
To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
• The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
• To maintain the nominal voltage, cast the terminals on the inside.
 There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE.
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG
Pitch: 10.1 mm
Width [w]: 10.1 mm
External dimensions
Height [h1]: 24 mm
Length [l1]: 18.1 mm
Internal dimensions
Height [h2]: 31 mm
Length [l2]: 24 mm
Mechanical testsTest for conductor damage and slackening
Specification: IEC 60947-7-1:2009-04
Result: Test passed
Pull-out test
Specification: IEC 60947-7-1:2009-04
Conductor cross section/conductor type/tractive force setpoint/actual value: 0.5 mm² / solid / > 20 N
0.5 mm² / flexible / > 20 N
16 mm² / solid / > 100 N
10 mm² / flexible / > 90 N
Electrical testsTemperature-rise test
Specification: IEC 60947-7-1:2009-04
Requirement temperature-rise test: Increase in temperature ≤45K
Short-time withstand current
Specification: IEC 60947-7-1:2009-04
Air clearances and creepage distances | 1. Insulation coordination
Application: Metal wall 1.0mm...2.5mm
Internal part molded
Specification: IEC 60947-7-1:2009-04
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 400 V
Rated surge voltage (III/3): 6 kV
minimum clearance value - non-homogenous field (III/3): 5.5 mm
minimum creepage distance (III/3): 5.5 mm
Rated insulation voltage (III/2): 500 V
Rated surge voltage (III/2): 6 kV
minimum clearance value - non-homogenous field (III/2): 5.5 mm
minimum creepage distance (III/2): 5.5 mm
Rated insulation voltage (II/2): 1000 V
Rated surge voltage (II/2): 6 kV
minimum clearance value - non-homogenous field (II/2): 5.5 mm
minimum creepage distance (II/2): 5.5 mm
Air clearances and creepage distances | 2. Insulation coordination
Application: Metal wall >2.5mm...4.0mm
Internal part molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 250 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 3.2 mm
Rated insulation voltage (III/2): 250 V
Rated surge voltage (III/2): 4 kV
minimum clearance value - non-homogenous field (III/2): 3 mm
minimum creepage distance (III/2): 3 mm
Rated insulation voltage (II/2): 500 V
Rated surge voltage (II/2): 4 kV
minimum clearance value - non-homogenous field (II/2): 3 mm
minimum creepage distance (II/2): 3 mm
Air clearances and creepage distances | 3. Insulation coordination
Application: Plastic panel
Internal part molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 500 V
Rated surge voltage (III/3): 6 kV
minimum clearance value - non-homogenous field (III/3): 5.5 mm
minimum creepage distance (III/3): 6.3 mm
Rated insulation voltage (III/2): 500 V
Rated surge voltage (III/2): 6 kV
minimum clearance value - non-homogenous field (III/2): 5.5 mm
minimum creepage distance (III/2): 5.5 mm
Rated insulation voltage (II/2): 1000 V
Rated surge voltage (II/2): 6 kV
minimum clearance value - non-homogenous field (II/2): 5.5 mm
minimum creepage distance (II/2): 5.5 mm
Air clearances and creepage distances | 4. Insulation coordination
Application: Plastic panel with DP-HDFK 10-5,5
Internal part molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 800 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 10 mm
Rated insulation voltage (III/2): 1000 V
Rated surge voltage (III/2): 8 kV
minimum clearance value - non-homogenous field (III/2): 8 mm
minimum creepage distance (III/2): 8 mm
Rated insulation voltage (II/2): 1000 V
Rated surge voltage (II/2): 8 kV
minimum clearance value - non-homogenous field (II/2): 8 mm
minimum creepage distance (II/2): 8 mm
Air clearances and creepage distances | 5. Insulation coordination
Application: without spacer plate
Internal part not molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 500 V
Rated surge voltage (III/3): 6 kV
minimum clearance value - non-homogenous field (III/3): 5.5 mm
minimum creepage distance (III/3): 6.3 mm
Rated insulation voltage (III/2): 600 V
Rated surge voltage (III/2): 6 kV
minimum clearance value - non-homogenous field (III/2): 5.5 mm
minimum creepage distance (III/2): 5.5 mm
Rated insulation voltage (II/2): 1000 V
Rated surge voltage (II/2): 6 kV
minimum clearance value - non-homogenous field (II/2): 5.5 mm
minimum creepage distance (II/2): 5.5 mm
Air clearances and creepage distances | 6. Insulation coordination
Application: with spacer plate and plastic panel (CTI 600)
Internal part not molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 800 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 10 mm
Rated insulation voltage (III/2): 1000 V
Rated surge voltage (III/2): 8 kV
minimum clearance value - non-homogenous field (III/2): 8 mm
minimum creepage distance (III/2): 8 mm
Rated insulation voltage (II/2): 1000 V
Rated surge voltage (II/2): 8 kV
minimum clearance value - non-homogenous field (II/2): 8 mm
minimum creepage distance (II/2): 8 mm
Air clearances and creepage distances | 7. Insulation coordination
Application: with spacer plate and metal panel
Internal part not molded
Specification: IEC 60947-1:2007-06 + A1:2010-12
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 300 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 4 mm
Rated insulation voltage (III/2): 300 V
Rated surge voltage (III/2): 4 kV
minimum clearance value - non-homogenous field (III/2): 3 mm
minimum creepage distance (III/2): 4 mm
Rated insulation voltage (II/2): 600 V
Rated surge voltage (II/2): 4 kV
minimum clearance value - non-homogenous field (II/2): 3 mm
minimum creepage distance (II/2): 3.2 mm
Environmental and real-life conditionsVibration test
Specification: IEC 60068-2-6:2007-12
Frequency: 10 - 150 - 10 Hz
Sweep speed: 1octave/min
5g (60.1Hz...150Hz)
Amplitude: 0.35mm (10Hz...60.1Hz)
Test duration per axis: 2.5 h
Glow-wire test
Specification: IEC 60695-2-11:2014-02
Temperature: 960°C
Time of exposure: 30 s
Ambient conditions
Ambient temperature (operation): -40°C ... 100°C (Depending on the current carrying capacity/derating curve)
Ambient temperature (storage/transport): -40°C ... 70°C
Relative humidity (storage/transport): 30 % ... 70 %
Ambient temperature (assembly): -5°C ... 100°C
Packaging specificationsType of packaging: packed in cardboard
Technical Specs
ECLASSECLASS-11.0: 27141134
ECLASS-13.0: 27141134
ECLASS-12.0: 27141134
ETIMETIM 9.0: EC001283
UNSPSCUNSPSC 21.0: 39121400