Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/97375d412c926547bb2e1a41b7a47993/-S204x204-FJPG Width: 35 mm Height: 129.9 mm Depth: 54 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). |
Interfaces | AxiolineFlocal bus Number of interfaces: 2 Connection method: Bus base module Transmission speed: 100 Mbps |
System properties | Module Input address area: 0 Byte Output address area: 4 Byte Required parameter data: 1 Byte Required configuration data: 6 Byte |
Output data | Digital Output name: Digital outputs Connection method: Push-in connection Connection technology: 1-conductor Number of outputs: 32 Protective circuit: Short-circuit protection, overload protection of the outputs; electronic Output voltage: 24 VDC Limitation of the voltage induced on circuit interruption: -32.8 V ... -15 V Maximum output current per module: 16 A (provide external protection) Nominal output voltage: 24 VDC Load min.: 10 ké Output voltage when switched off: max. 1 V Output current when switched off: max. 300 µA Nominal load, inductive: max. 12 VA (1.2 H, 48 é, with nominal voltage) Nominal load, lamp: max. 12 W (at nominal voltage) Nominal load, ohmic: max. 12 W (48 é, with nominal voltage) Switching frequency: max. 5500 per second (with ohmic load) max. 1 per second (with inductive load) max. 16 per second (with nominal lamp load) Reverse voltage resistance to short pulses: limited protection up to 0.5 A for 1 s Behavior with overload: Shutdown with automatic restart Behavior with inductive overload: Output can be destroyed Signal delay: max. 150 µs (when switched on) max. 200 µs (during switching off with ohmic nominal load) Overcurrent shut-down: as of 0.7 A Output current with ground connection interrupt when switched off: < 1 mA |
Product properties | Type: block modular Product type: I/O component Product family: AxiolineF Mounting position: any (no temperature derating) Scope of delivery: including bus base module and AxiolineF connectors Insulation characteristics Overvoltage category: II (IEC 60664-1, EN60664-1) Pollution degree: 2 (IEC 60664-1, EN60664-1) |
Electrical properties | Maximum power dissipation for nominal condition: 2.7 W Potentials: AxiolineF local bus supply (U Supply voltage: 5 VDC (via bus base module) Current draw: max. 60 mA Power consumption: max. 300 mW Potentials: Supply for digital output modules (U Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 16 A (Provide external protection; if the total current of 8A is exceeded, connect the supply at the power connector parallel via both terminal points.) Power consumption: max. 480 W (of which 2.4W constitute internal losses) Protective circuit: Surge protection; electronic (35 V, 0.5 s) Reverse polarity protection; parallel diode; with external 5A fuse (only for commissioning) Electrical isolation/isolation of the voltage ranges Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min. Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: AxiolineF connector Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. With a small conductor cross section and high current, the terminal point temperature can reach up to 31K above the ambient temperature. When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm AxiolineF connector Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. With a small conductor cross section and high current, the terminal point temperature can reach up to 31K above the ambient temperature. When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL. Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Mounting | Mounting type: DIN rail mounting Mounting position: any (no temperature derating) |
ECLASS | ECLASS-11.0: 27242604 ECLASS-12.0: 27242604 ECLASS-13.0: 27242604 |
ETIM | ETIM 9.0: EC001599 |
UNSPSC | UNSPSC 21.0: 32151600 |