Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1038567
PHOENIX CONTACT 1038567
PHOENIX CONTACTNot available

TC MOBILE I/O X200-4G - SMS relay

SMS relay and signaling module, European version, monitor analog and digital values via cellular network, switch relay outputs remotely, communication via SMS or cellular network data connection (e-mail transmission, app), supply voltage 10V...60VDC
Product Code: 1038567
Partner cod.: 1038567
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Signaling system
Application: I/O
MTTF: 674 Years (SN29500 standard, temperature25°C, operating cycle21%)
324 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
130 Years (SN29500 standard, temperature40°C, operating cycle100%)
Electrical propertiesMains type: Cellular communication
Supply
Supply voltage range: 10 VDC ... 60 VDC
Typical current consumption: 50 mA (24VDC)
Max. current consumption: 80 mA
Input dataDigital
Description of the input: Digital input
Number of inputs: 4
Switching threshold "0" signal in reference to UN: ≤ 0.3
Switching threshold "1" signal in reference to UN: ≥ 0.7
Analog
Description of the input: Analog input
Number of inputs: 2
Input signal: Current or voltage
Resolution: 15 bit
Input impedance: 600 kΩ (Voltage inputs)
50 Ω (Current inputs)
Voltage input signal: 0 VDC ... 60 VDC
Current input signal: 0 mA ... 20 mA
4 mA ... 20 mA (configurable)
Precision: ± 0.1 %
Output dataSwitching
Output name: Relay output
Number of outputs: 4
Contact switching type: N/O contact
Minimum switching voltage: 100 mV
Maximum switching voltage: 60 VDC
30 VAC
Limiting continuous current: 6 A
Switching capacity: 100 W (Power Source PS2, Pout ≤100W)
Electrical service life: 30000 cycles
Connection dataSupply
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 2.5 mm²
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 24 ... 14
Stripping length: 6.5 mm
Tightening torque: 0.5 Nm ... 0.6 Nm (5-7 lbs-in, screw terminal blocks)
InterfacesData: USB 2.0
Connection method: Mini-USB type B, 5-pos.
Transmission length: ≤ 3 m (only for configuration and diagnostics)
Wireless
Interface description: GSM / GPRS / EDGE / LTE (FDD)
Frequency range: 800 MHz (LTE B20)
1800 MHz (LTE B3)
2600 MHz (LTE B7)
900 MHz (2 W (EGSM))
1800 MHz (1W (EGSM))
GPRS: Multislot Class33
EDGE: Multislot Class33
LTE: CAT1
DimensionsWidth: 72 mm
Height: 90 mm
Depth: 62 mm
Material specificationsMaterial: Polycarbonate
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (SMS mode only, note the derating information in the technical documentation for data connection)
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: 2000 m
Permissible humidity (operation): 0 % ... 95 %
ApprovalsCE
Certificate: CE-compliant
Wireless approval, Europe
Note: RED 2014/53/EU
UKCA
Certificate: UKCA-compliant
EMC dataElectromagnetic compatibility: Conformance with RED Directive 2014/53/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV
Discharge in air: ± 8 kV
Indirect discharge: ± 6 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 26 MHz ... 6 GHz
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2 kV (Unshielded supply line)
Signal: ± 2 kV (Shielded signal line)
± 2 kV (Analog I/O cables, unshielded)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV (Symmetrical, unshielded supply line)
± 0.5 kV (Asymmetrical, unshielded supply line)
Signal: ± 1 kV (Data line, asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Emitted interference
Emitted radio interference in acc. with EN 55011: ClassB, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsStandards/regulations: EN50360
EN50121-4
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27371216
ECLASS-13.0: 27371216
ECLASS-12.0: 27371216
ETIMETIM 9.0: EC000225
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00198.pdf

Application_note_00053.pdf

Application_note_00194.pdf

Application_note_00119.pdf

Application_note_00197.pdf

Data_sheet_00253.pdf

Manual_00027.pdf

Manufacturer_declaration_01110.pdf

Manufacturer_declaration_01542.pdf

Manufacturer_declaration_05534.pdf

Manufacturer_declaration_05976.pdf

Manufacturer_declaration_17707.pdf

Package_slip_02409.pdf