Industrial Automation
Input data | Nominal input voltage range: 12 VDC ... 24 VDC Input voltage range: 12 VDC ... 24 VDC -25%...+33% (SELV) Wide-range input: yes Electric strength, max.: 35 VDC (60 s) Inrush current: typ. 8.6 A Inrush current integral (I2t): typ. 0.1 A2s Inrush current limitation: 8.6 A Mains buffering time: typ. 16 ms (24VDC) Current consumption: typ. 7.2 A (12VDC) typ. 3.5 A (24VDC) Switch-on time: < 1 s Input fuse: 15 A (fast blow, internal) Recommended breaker for input protection: 10 A ... 16 A (Characteristic B, C, D, K or comparable) |
Output data | Efficiency: typ. 92.1 % (24VDC) Output characteristic: U/I Advanced Smart HICCUP FUSE MODE Nominal output voltage: 24 VDC Setting range of the output voltage (USet): 24 VDC ... 28 VDC (> 24VDC, constant capacity) Nominal output current (IN): 2.5 A Static Boost (IStat.Boost): 3.125 A (â¤40°C) Dynamic Boost (IDyn.Boost): 5 A (â¤60°C(4.9s)) Short-circuit-proof: yes No-load proof: yes Derating: > 60°C (2.5%/K of POut nom.) Output power (PN): 60 W Output power (PStat. Boost): 75 W Output power (PDyn. Boost): 120 W Feedback voltage resistance: ⤠35 VDC Protection against overvoltage at the output (OVP): ⤠32 VDC Residual ripple: < 20 mVPP Control deviation: < 1 % (change in load, static 10 % ... 90 %) Rise time: < 1 s (UOUT (10 % ... 90 %)) Connection in series: yes Maximum no-load power dissipation: < 1.3 W Power loss nominal load max.: < 8 W Connection in parallel: yes, for redundancy and increased capacity Signal (configurable) Digital: 0 VDC 24 VDC 22 mA Default: 24 VDC 22 mA 24VDC for UOut >0.9xUSet |
Connection data | Input Position: 1.x Conductor connection Connection method: Push-in connection rigid: 0.75 mm² ... 2.5 mm² flexible: 0.75 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve: 0.75 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve: 0.75 mm² ... 2.5 mm² rigid (AWG): 18 ... 14 Stripping length: 10 mm Output Position: 2.x Conductor connectionâ Connection method: Push-in connection rigid: 0.5 mm² ... 2.5 mm² flexible: 0.5 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve: 0.5 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve: 0.5 mm² ... 2.5 mm² rigid (AWG): 20 ... 14 Stripping length: 10 mm Signal Position: 3.x Conductor connectionââ Connection method: Push-in connection rigid: 0.2 mm² ... 2.5 mm² flexible: 0.2 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve: 0.25 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve: 0.25 mm² ... 2.5 mm² rigid (AWG): 24 ... 14 Stripping length: 10 mm |
Signaling | LED signaling Signal threshold: > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting) > 0.9xUSet (LED lights up green) < 0.9xUSet (LED flashes green) |
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 2.6 kV DC (type test) 1.2 kV DC (routine test) Switching frequency: 130 kHz ... 130 kHz (Auxiliary converter stage) 70 kHz ... 250 kHz (Main converter stage) |
Product properties | Product type: DC/DC converters Product family: QUINT POWER MTBF (IEC 61709, SN 29500): > 1999348 h (25°C) > 1120490 h (40°C) > 471066 h (60°C) Insulation characteristics Protection class: II Degree of pollution: 2 Life expectancy (electrolytic capacitors) Current: 1.25 A Temperature: 40°C Time: 242000 h Additional text: 24VDC Life expectancy (electrolytic capacitors)â Current: 2.5 A Temperature: 40°C Time: 160000 h Additional text: 24VDC Life expectancy (electrolytic capacitors)ââ Current: 2.5 A Temperature: 30°C Time: 320000 h Additional text: 24VDC |
Dimensions | Item dimensions Width: 32 mm Height: 106 mm Depth: 90 mm Item dimensions with alternative mounting Width: 90 mm Height: 106 mm Depth: 32 mm Installation dimensions Installation distance right/left (active): 15 mm / 15 mm (POutâ¥50%) Installation distance right/left (passive): 5 mm / 5 mm (POutâ¥50%) Installation distance right/left (active, passive): 0 mm / 0 mm (POutâ¤50%) Installation distance top/bottom (active): 30 mm / 30 mm (POutâ¥50%) Installation distance top/bottom (passive): 30 mm / 30 mm (POutâ¥50%) Installation distance top/bottom (active, passive): 30 mm / 30 mm (POutâ¤50%) |
Mounting | Mounting type: DIN rail mounting Assembly instructions: alignable: PN â¥50%, 5mm horizontally, 15mm next to active components, 50mm vertically alignable: PN <50%, 0mm horizontally, 40mm vertically top, 20 mm vertically bottom With protective coating: No |
Material specifications | Flammability rating according to UL94 (housing / terminal blocks): V0 Housing material: Plastic Type of housing: Polycarbonate (PC), UL94V0 |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (start-up type tested): -40°C Maximum altitude: ⤠5000 m (> 2000 m, observe derating) Climatic class: 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation): ⤠95 % (at 25°C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): < 15Hz, ±2.5mm amplitude; 15Hz ... 100Hz: 2.3g 90Min. (in accordance with IEC 60068-2-6) |
Standards and regulations | Overvoltage category EN 61010-1: II(â¤5000m) Safety for measurement, control, and laboratory equipment Standard designation: Electrical safety (of control and regulation devices) Standards/specifications: IEC 61010-1 Protective extra-low voltage Standard designation: Protective extra-low voltage Standards/specifications: IEC 61010-1 (SELV) Mains voltage dips Standard designation: Mains variation/undervoltage Standards/specifications: EN61000-4-29 |
Approvals | SIQ: CB-Scheme (IEC 61010-1, IEC 61010-2-201) UL approvals: UL Listed UL61010-1 UL Listed UL61010-2-201 ANSI/UL121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) UL Identification: ULListedUL61010-1 ULâ Identification: CAN/CSAC22.2 No.61010-1-12 ULââ Identification: ULListedUL61010-2-201 ULâââ Identification: CAN/CSAC22.2No.61010-2-201:18 ULââââ Identification: UL121201 & CSAC22.2No.213-17Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) CB scheme Identification: IEC 61010-1 CB schemeâ Identification: IEC 61010-2-201 Shipbuilding Identification: DNV GL |
EMC data | EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU EMC requirements, power plant: EN61850-3 EN61000-6-5 Conducted noise emission: EN55016 EN61000-6-3 (Class B) Noise emission: Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) EN55016 EN61000-6-3 (Class B) DNVGL conducted interference: ClassB Additional text: Bridge and deck area DNVGL noise radiation: ClassB Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 6 kV (Test Level 4) Discharge in air: 8 kV (Test Level 3) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 6 GHz Test field strength: 20 V/m (Test Level 3) 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 2 kV (Test Level 4 - asymmetrical) Output: 2 kV (Test Level 4 - asymmetrical) Signal: 2 kV (Test Level 4 - asymmetrical) Comments: Criterion B Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 1 kV (Test Level 4 - symmetrical) 2 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal: 1 kV (Test Level 4 - symmetrical) 2 kV (Test Level 4 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ I/O/S: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Power frequency magnetic field Standards/regulations: EN61000-4-8 Frequency: 16.67 Hz 50 Hz 60 Hz 50 Hz 60 Hz 0 Hz Test field strength: 100 A/m 1 kA/m 300 A/m Additional text: 60 s 3 s DC, 60s Comments: Criterion A Frequency range: 50 Hz ... 60 Hz Voltage dips Standards/regulations: EN61000-4-29 Voltage: 24 VDC Voltage dip: 70 % 40 % 0 % Number of periods: 0.5 / 1 / 25 periods 5 / 10 / 50 periods 0.5 / 1 / 5 / 50 periods Time: 100 ms 50 ms Additional text: Test Level 2 Comments: Criterion A Criterion B Pulse-shape magnetic field Standards/regulations: EN61000-4-9 Test field strength: 1000 A/m Comments: Criterion A Asymmetrical conducted disturbance variables Standards/regulations: EN61000-4-16 Test level 1: 15 Hz 150 Hz (Test Level 3) Voltage: 10 V 1 V (Permanent) 1 V 1 V 10 V 10 V 10 V (Permanent) 100 V (1 s) Test level 2: 150 Hz 1.5 kHz (Test Level 3) Test level 3: 1.5 kHz 15 kHz (Test Level 3) Test level 4: 15 kHz 150 kHz (Test Level 3) Test level 5: 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) Test level 6: 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) Comments: Criterion A Alternating component of direct voltage Standards/regulations: EN61000-4-17 Alternating component: 10 % (UN) Frequency: 50 Hz 100 Hz 150 Hz 300 Hz Comments: Criterion A Attenuated oscillating wave Standards/regulations: EN61000-4-18 Input, output (test level1): 1 MHz (Test Level 2 - symmetrical) Voltage: 0.5 kV 1 kV 0.5 kV 1 kV Input, output (test level2): 1 MHz (Test Level 2 - asymmetrical) Signals (test level1): 1 MHz (Test Level 2 - symmetrical) Signals (test level2): 1 MHz (Test Level 2 - asymmetrical) Comments: Criterion A Attenuated oscillating magnetic field Standards/regulations: EN61000-4-10 Test field strength: 100 A/m Test level 1: 100 kHz Test level 2: 1 MHz Comments: Criterion A Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
ECLASS | ECLASS-11.0: 27040701 ECLASS-12.0: 27040701 ECLASS-13.0: 27040701 |
ETIM | ETIM 9.0: EC002540 |
UNSPSC | UNSPSC 21.0: 39121000 |