Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1072839
PHOENIX CONTACTNot available

IOL MA8 EIP DI8 - Communication module

Eight-channel IO-Link master provides convenient configuration of IO-Link devices using web-based management. Supports connectivity to EtherNet/IP, MODBUS, and OPCUA. Features eight auxiliary digital inputs, redundant input power supply connections, plug-in push-in terminals.
Product Code: 1072839
Partner cod.: 1072839
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsWidth: 45 mm
Height: 114.5 mm
Depth: 99 mm
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Material specificationsHousing material: Polyamide
Color: gray
InterfacesEtherNet/IP™
No. of channels: 2
Connection method: RJ45 jack
Transmission speed: 10/100 Mbps (with auto negotiation)
Transmission physics: Ethernet in RJ45 twisted pair
EtherNet/IP™â€‹
Equipment type: EtherNet/IP™ device
Input dataDigital
Input name: Digital inputs
Description of the input: IEC 61131-2 type 1
Number of inputs: 8
Connection method: Push-in / plug connection
Connection technology: 3-conductor
Input voltage range "0" signal: 0 VDC ... 5 VDC
Input voltage range "1" signal: 15 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: typ. 3.5 mA
Input frequency: 0.5 kHz
Protective circuit: Overload protection
Short-circuit protection for the sensor supply
Digital​
Input name: Digital inputs
Description of the input: IO-Link ports in digital input (DI) mode
Number of inputs: max. 8 (EN 61131-2 types 1 and 3)
Connection method: Push-in / plug connection
Connection technology: 3-conductor
Nominal input voltage UIN: 24 VDC
Input voltage range "0" signal: 8 VDC ... 11.5 VDC (for C/Q pin)
Input voltage range "1" signal: 10.5 VDC ... 13 VDC
Sensor current per channel: max. 200 mA (from L+/L-)
Total sensor current: max. 1.6 A (from L+/L-)
Protective circuit: Overload protection; yes
Short-circuit protection for the sensor supply; electronic
IO-Link
Description of the input: Digital inputs (DI)
Connection method: Push-in / plug connection
Nominal input voltage UIN: 24 VDC
Input voltage range "0" signal: 5.2 VDC ... 6.4 VDC
Input voltage range "1" signal: 6.8 VDC ... 8 VDC
Nominal input current: typ. 3.5 mA
Sensor current per channel: max. 200 mA (from L+/L-)
Total sensor current: max. 1.6 A (from L+/L-)
Protective circuit: Overload protection; yes
Short-circuit protection for the sensor supply; yes
IO-Link​
Number of ports: 8
Connection method: Push-in / plug connection
Connection technology: 3-conductor
Cycle Time: min. 4 ms (IO-Link cycle time)
Output dataDigital
Maximum output current per channel: 200 mA
Digital​
Output description: IO-Link ports in digital output (DO) mode
Connection method: Push-in / plug connection
Connection technology: 3-conductor
Number of outputs: max. 8
Nominal output voltage: 24 VDC
Maximum output current per channel: 200 mA
Maximum output current per module: 1.6 A
Nominal load, ohmic: 4.8 W (120Ω, at nominal load)
Output voltage when switched off: max. 1 V
Output current when switched off: max. 400 µA
Protective circuit: Overload protection
Short-circuit protection; yes
Behavior with overload: Shutdown with automatic restart
Product propertiesType: Stand-Alone
Product type: I/O component
Product family: Stand-Alone
Electrical propertiesSupply: IO-Link
Nominal voltage for I/O supply: 24 VDC
Nominal current for every IO-Link port: max. 200 mA (at C/Q)
max. 200 mA (at L+/L-)
Permissible cable length: < 20 m
Protective circuit: Overload protection; yes
Potentials
Supply voltage: 24 VDC
Supply voltage range: 10.8 VDC ... 30 VDC
Current draw: 155 mA
Supply: Module electronics
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 30 VDC
Current consumption: 3.7 A
Supply:
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 30 VDC
Current consumption: max. 3.7 A
Typical current consumption: 155 mA (at 24 V DC)
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply/Ethernet: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (US) / FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Ethernet/FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Ethernet/Ethernet: 500 VAC, 50 Hz, 1 min.
Connection dataConductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
Stripping length: 10 mm
Conductor cross section, rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 2.5 mm²
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 10 % ... 95 %
Permissible humidity (storage/transport): 10 % ... 95 %
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27242608
ECLASS-12.0: 27242608
ECLASS-13.0: 27242608
ETIMETIM 9.0: EC001604
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01328.pdf

Approvals_01329.pdf

Manual_00043.pdf

Manufacturer_declaration_00207.pdf

Package_slip_00130.pdf

Technical_drawing_07526.pdf

Various_00004.pdf