PHOENIX CONTACT 1088129
PHOENIX CONTACT 1088129
PHOENIX CONTACTAvailable

AXL SE DO16/1 - Digital module

Axioline SmartElements, Digital output module, Digital outputs:16, 24 VDC, 500 mA, connection technology:1-conductor, degree of protection: IP20
Product Code: 1088129
Partner cod.: 1088129
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesSmartElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartElement.
Start time until ready to operate: < 500 ms
System propertiesModule
ID code (hex): none
Process data channel: 16 bit
Input address area: 0 Byte
Output address area: 2 Byte
Required parameter data: 9 Byte
Required configuration data: 6 Byte
Output dataDigital
Output name: Digital outputs
Connection method: Push-in connection
Connection technology: 1-conductor
Number of outputs: 16
Protective circuit: Short-circuit and overload protection; electronic
Output voltage: 24 V
Limitation of the voltage induced on circuit interruption: -32.8 VDC ... -15 VDC
Maximum output current per module: 6 A (Also make sure that the maximum permissible current of 6A is not exceeded.)
Nominal output voltage: 24 VDC
Load min.: 10 kΩ
Output voltage when switched off: max. 1 V
Output current when switched off: max. 300 µA
Nominal load, inductive: 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp: 12 W (at nominal voltage)
Nominal load, ohmic: 12 W (48 Ω, with nominal voltage)
Switching frequency: max. 1200 per second (With resistive load, at least 50mA load current)
max. 1 per second (with inductive load)
max. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulses: limited protection up to 0.5 A for 1 s
Behavior with overload: Shutdown with automatic restart
Behavior with inductive overload: Output can be destroyed
Signal delay: max. 100 µs (when switched on)
max. 100 µs (when switched off, with at least 50 mA load current)
Overcurrent shut-down: min. 0.7 A
Output current with ground connection interrupt when switched off: < 1 mA
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartElements
Mounting position: See the system in which the SmartElement is used.
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesPotentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VDC (using card edge connectors)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 6 A
Current consumption: min. 40 mA (without connected peripherals)
Power consumption: max. 180 W (of which 1.1W internal losses)
min. 288 mW
Protective circuit: Surge protection; See the system in which the SmartElement is used.
Reverse polarity protection; parallel diode
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
With a small conductor cross section and high current, the terminal point temperature can reach up to 45K above the ambient temperature.
When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
With a small conductor cross section and high current, the terminal point temperature can reach up to 45K above the ambient temperature.
When selecting the cables, observe the permissible operating temperature in accordance with IEC or UL.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Smart Element slot
Mounting position: See the system in which the SmartElement is used.
Technical Specs
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Description
Axioline Smart Elements, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection method: 1-wire, degree of protection: IP20
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00139.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Approvals_01938.pdf

Approvals_01945.pdf

Approvals_01952.pdf

Approvals_01953.pdf

Data_sheet_00558.pdf

Manual_00006.pdf

Manual_00045.pdf

Manual_00007.pdf

Manufacturer_declaration_01284.pdf

Manufacturer_declaration_02306.pdf

Manufacturer_declaration_04371.pdf

Manufacturer_declaration_06297.pdf

Product_information_00033.pdf

Product_information_00051.pdf

Technical_drawing_08042.pdf