Industrial Automation
ELR H51-IES-24DC500AC-3-IOL - Hybrid motor starter
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | Product type: Hybrid motor starters Product family: CONTACTRON Operating mode: 100% operating factor Insulation characteristics: Standards/regulations Pollution degree: 2 |
Electrical properties | Number of phases: 3 Motor starter type: Reversing starter Switching frequency: ⤠2 Hz (Load-dependent) Maximum power dissipation: 4.1 W Minimum power dissipation: 0.88 W Coordination type: 1 Supply Rated control circuit supply voltage US: 24 VDC Control supply voltage range: 19.2 VDC ... 30 VDC Rated control supply current IS: 65 mA Protective circuit: Surge protection Reverse polarity protection; Parallel polarity protection diode Supply: IO-Link Nominal voltage for I/O supply: 24 VDC (This supply voltage is provided via the IO-Link interface of the IO-Link master.) Current consumption: typ. 65 mA ±15% (24VDC) max. 150 mA Protective circuit: Reverse polarity protection Short-circuit protection Overload protection Insulation characteristics Rated insulation voltage: 550 V Rated surge voltage: 6 kV Overvoltage category: III Degree of pollution: 2 Insulation characteristics between control input voltage and control supply voltage to main circuit: Safe isolation (IEC 60947-1) Emergency tripping Operate threshold: > 33 A Response time: < 0.5 s |
Input data | Control Input name: Enable input Rated actuating voltage UC: 24 VDC Triggering voltage range: 19.2 VDC ... 30 VDC Rated actuating current IC: 7 mA Switching threshold: 9.6 V (â0â signal) 19.2 V (â1â signal) Switching level: < 5 VDC (For EMERGENCY STOP) Typical turn-off time: < 30 ms IO-Link Number of ports: 1 Connection method: COMBICON Connection technology: 3-conductor Specification: V1.1.1 Reverse polarity protection: yes Cycle Time: 30 ms Amount of process data: 8 Byte (Input data) 2 Byte (Output data) |
Output data | AC output Rated operating voltage Ue: 500 VAC Operating voltage range: 42 VAC ... 550 VAC Rated operating current Ie: 3 A (AC-51) 3 A (AC-53a) Mains frequency: 50/60 Hz Load current range: 180 mA ... 3 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2: Class 10 Cooling time: 20 min. (for auto reset) Leakage current: 0 mA Protective circuit: Surge protection; Varistor |
Connection data | Control circuits Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 14 Load circuit Connection method: Screw connection Stripping length: 8 mm Screw thread: M3 Conductor cross section rigid: 0.2 mm² ... 2.5 mm² Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 14 Tightening torque: 0.5 Nm ... 0.6 Nm 5 lbf-in. ... 7 lbf-in. |
Signaling | Status display: Yellow LED Operating voltage display: Green LED Error indication: Red LED |
Dimensions | Width: 22.5 mm Height: 160 mm Depth: 114.5 mm |
Material specifications | Flammability rating according to UL 94: V0 (Housing) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -5°C ... 60°C (observe derating) Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m |
Approvals | UKCA Certificate: UKCA-compliant UL approval Certificate: NLDX.E228652 NRNT.E172140 Safety Integrity Level (SIL, IEC 61508) Identification: â¤3 Note: Safe shutdown Performance Level (ISO13849) Identification: e Note: Safe shutdown Category (ISO13849) Identification: â¤3 Note: Safe shutdown UL data SCCR: 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) FLA: 3 A (480VAC) Group installation: 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) Category code: NLDX / NRNT Horsepower ratings: 0.5 hp (120VAC/208VAC) 1.5 hp (277VAC/480VAC) |
Standards and regulations | Standards/regulations Standards/regulations: IEC 60947-1 EN60947-4-2 IEC 61508 ISO13849-1 |
Mounting | Assembly instructions: alignable, for spacing see derating Mounting position: vertical (horizontal DIN rail, motor output below) |
ECLASS | ECLASS-11.0: 27370905 ECLASS-13.0: 27370905 ECLASS-12.0: 27370905 |
ETIM | ETIM 9.0: EC001037 |
UNSPSC | UNSPSC 21.0: 25173900 |
Description other products