Industrial Automation
Notes | General: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. FE not connected to metal parts that can be touched, no protective function Lock nut is included in the scope of delivery |
Mounting | Mounting type: Rear mounting M16 x 1.5 With flat nut Assembly instructions: With flat nut Connection method: Individual wires |
Product properties | Product type: Circular connectors (device side) Sensor type: Power Number of positions: 5 No. of cable outlets: 1 Shielded: no Coding: L Thread type: M12 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Material specifications | Flammability rating according to UL 94: V0 Seal material: FKM Contact material: CuZn Contact surface material: Au Contact carrier material: PA Material for screw connection: Zinc die-cast, nickel-plated Conductor material: Tin-plated Cu litz wires |
Electrical properties | Rated voltage in acc. with IEC 61076-2-101: 63 V Rated surge voltage: 1.5 kV 1.5 kV AC/DC Nominal voltage UN: 63 V Nominal current IN: 16 A Test voltage: 1.5 kV Test voltage Core/Core: 6 kV |
Connection data | Conductor connection Connection method: Individual wires Contact connection type: Pin Conductor cross section: 2.5 mm² Tightening torque: 0.8 Nm 1.3 Nm |
Connector | Connection 1 Head design: Pin Head cable outlet: straight Head thread type: M12 Coding: L Connection 2 Head design: free cable end |
Cable/line | Cable length: 1.5 m Cable type: PEX litz wire Signal type/category: Power Single wire, color: brown 1, white 2, blue 3, black 4, pink FE Cable cross section: 2.5 mm² Conductor material: Tin-plated Cu litz wires AWG signal line: 10 Material wire insulation: PE-X Test voltage Core/Core: 6 kV Halogen-free: according to IEC 60754-1 Flame resistance: in acc. with UL FT-2 Other resistance: Hydrolysis-resistant Ambient temperature (operation): -25°C ... 90°C -40°C ... 90°C (cable, fixed installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 IP65/IP67 Ambient temperature (operation): -40°C ... 85°C (without mechanical actuation) -25°C ... 90°C -40°C ... 90°C (cable, fixed installation) |
Standards and regulations | Flame resistance: in acc. with UL FT-2 Other resistance: Hydrolysis-resistant M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-111 Note: In line with |
ECLASS | ECLASS-11.0: 27440102 ECLASS-12.0: 27440116 ECLASS-13.0: 27440116 |
ETIM | ETIM 9.0: EC002635 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products