Industrial Automation
Notes | General Note: The current is determined by the fuse used, the voltage by the fuse or selected light indicator. The maximum load current of a single clamping unit must not be exceeded. For power distribution applications, IEC 60364-4-43.2008; modified + corrigendum Okt. 2008 (DINVDE0100-430:2010-10) section433.2 ff must be observed! |
Product properties | Product type: Distributor terminal block Number of connections: 7 Number of rows: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Electrical properties | Rated surge voltage: 8 kV Maximum power dissipation for nominal condition: 1.02 W Fuse: G / 5 x 20 LED voltage range: 110 V AC/DC ... 250 V AC/DC LED current range: 0.41 mA ... 0.96 mA Maximum power dissipation: max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) |
Input data | LED voltage range: 110 V AC/DC ... 250 V AC/DC |
Connection data | Number of connections per level: 7 Load contact Stripping length: 10 mm ... 12 mm Internal cylindrical gage: A4 Connection in acc. with standard: IEC 60947-7-3 Conductor cross section rigid: 0.2 mm² ... 6 mm² Cross section AWG: 24 ... 10 (converted acc. to IEC) Conductor cross section flexible: 0.2 mm² ... 4 mm² Conductor cross section, flexible [AWG]: 24 ... 12 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.2 mm² ... 0.4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.2 mm² ... 4 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 1 mm² Nominal current: 6.3 A (the current is determined by the fuse used) Maximum load current: 6.3 A (with 4mm² conductor cross section) Maximum total current: 37.8 A (The maximum load current of the individual terminal point must not be exceeded.) Nominal voltage: 250 V (the voltage is determined by the light indicator.) Nominal cross section: 4 mm² Line contact Stripping length: 12 mm ... 14 mm Conductor cross section rigid: 0.5 mm² ... 16 mm² Cross section AWG: 20 ... 6 (converted acc. to IEC) Conductor cross section flexible: 0.5 mm² ... 10 mm² Conductor cross section, flexible [AWG]: 20 ... 8 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 10 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 10 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 4 mm² Nominal current: 37.8 A Maximum load current: 37.8 A (with 10 mm² conductor cross section) Maximum total current: The maximum load current of the individual terminal point must not be exceeded. Nominal cross section: 16 mm² Load contact Connection cross sections directly pluggable Conductor cross section rigid: 0.5 mm² ... 6 mm² Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 4 mm² Line contact Connection cross sections directly pluggable Conductor cross section rigid: 1.5 mm² ... 10 mm² Conductor cross section, rigid [AWG]: 16 ... 8 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 1.5 mm² ... 10 mm² Flexible conductor cross section (ferrule with plastic sleeve): 1.5 mm² ... 10 mm² |
Dimensions | Width: 87.8 mm Height: 28.6 mm Depth: 35.4 mm |
Material specifications | Color: black Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Calorimetric heat release NFPA 130 (ASTM E 1354): 27,5 MJ/kg Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed |
Mechanical properties | Mechanical data Open side panel: No |
Environmental and real-life conditions | Oscillation/broadband noise Specification: DINEN50155 (VDE0115-200):2018-05 Spectrum: Service life test category2, bogie-mounted Frequency: f1 = 5 Hz to f2 = 250 Hz ASD level: 6.12 (m/s²)²/Hz Acceleration: 3.12g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINEN50155 (VDE0115-200):2018-05 Pulse shape: Half-sine Acceleration: 30g Shock duration: 18ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (operation): -60°C ... 105°C (max. short-term operating temperature RTI Elec.) Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (storage/transport): 30 % ... 70 % |
Standards and regulations | Connection in acc. with standard: IEC 60947-7-3 |
Mounting | Mounting type: for snapping onto a DIN rail adapter Direct mounting with flange Free-hanging |
ECLASS | ECLASS-11.0: 27141116 ECLASS-12.0: 27141116 ECLASS-13.0: 27250113 |
ETIM | ETIM 9.0: EC000899 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products