PHOENIX CONTACT 1185380
PHOENIX CONTACT 1185380
PHOENIX CONTACTNot available

AXL E IOL SDI8 SDO4 2A M12 L - Safety module

AxiolineE-safety module, 4safe digital inputs for 2-channel assignment, 8safe digital inputs for 1-channel assignment, 4safe digital +/-switching outputs, IO-Link interface, IP65/IP67 degree of protection, for PROFIsafe systems
Product Code: 1185380
Partner cod.: 1185380
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/2532a0c22627804baaabc1e0d9ea3b78/-S204x204-FJPG
Width: 59.8 mm
Height: 214 mm
Depth: 30 mm
Note on dimensions: Specifications including fixing clips and connectors
Material specificationsHousing material: Plastic POCAN B4239 GF30 YE 1018
Input dataDigital
Input name: Safe digital inputs
Description of the input: IEC 61131-2 type 3
Number of inputs: 4 (for 2-channel assignment)
8 (for 1-channel assignment)
Cable length: max. 200 m
Connection method: M12 connector (A-coded)
Connection technology: 3-conductor
Input voltage range "0" signal: -30 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30.2 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: typ. 3.7 mA (at 24 V DC)
max. 4.3 mA (with 30.2VDC)
Input filter time: 1.5 ms
3 ms (Default)
5 ms
15 ms
Protective circuit: Overload protection, short-circuit protection of sensor supply
IO-Link
Number of ports: 1
Connection method: M12 connector, A-coded
Connection technology: 3-conductor
Port type: Class A
Specification: V1.1.2
Reverse polarity protection: yes
Transmission speed: 230.4 kbps (COM3)
Cycle Time: ≥ 4 ms
Process data update: ≥ 4 ms
Amount of process data: 64 bit (Input and output data)
Output dataDigital
Output name: Safe digital outputs
Connection method: M12 connector (A-coded)
Connection technology: 2-conductor
Number of outputs: 4 (for 2-channel assignment, +/- switching)
4 (for 1-channel assignment, + switching)
Protective circuit: Overload protection, short-circuit protection of outputs
Output voltage: UA - 1.4V
Output current: max. 2 A (per channel)
max. 2 A (per output)
max. 6 A (Total current of all outputs; Please observe the notes in the user manual.)
Maximum output current per channel: 2 A
Nominal output voltage: 24 VDC (from voltage UA)
Load min.: 2.4 kΩ (10mA at 24VDC)
Output voltage when switched off: < 5 V ((in the Low state))
Output current when switched off: 2 mA (Leakage current in the Low state)
Delay time: max. 128 s (can be parameterized)
Permissible cable length: max. 50 m
Switching frequency: max. 1 Hz
Reverse voltage resistance to short pulses: no
Product propertiesType: Stand-Alone
Product type: I/O component
Product family: AxiolineE
Mounting position: any
Application: Functional safety
Operating mode: Process data mode with 4 words
Insulation characteristics
Pollution degree: 4
Electrical propertiesSupply: IO-Link
Designation: IO-Link port supply (L+)
Nominal voltage for I/O supply: 24 VDC (Provided via the IO-Link interface of the IO-Link master.)
Supply voltage range: 19.2 VDC ... 30.2 VDC (including all tolerances, including ripple)
Nominal current per device: approx. 15 mA
Permissible cable length: max. 20 m
Protective circuit: Reverse polarity protection
Supply: Module electronics and sensors
Designation: Supply of module electronics and sensors (US)
Connection method: M12 connector (L-coded)
Number of positions: 2
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30.2 VDC (including all tolerances, including ripple)
Current consumption: 67 mA (without sensors)
Protection: max. 8 A (slow-blow)
Supply: Actuators
Designation: Actuator supply (UA)
Connection method: M12 connector (L-coded)
Number of positions: 2
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30.2 VDC (including all tolerances, including ripple)
Current consumption: 52 A (without actuators)
Protection: max. 8 A (slow-blow)
Connection dataConnection method: M12 connector
Note on the connection method: in accordance with IEC 61076-2-101, M12 connection technology
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C (Mounting position: any)
Degree of protection: IP65/IP67 (in accordance with DINEN60529:1989 + A1:1999 + A2:2013)
Note: Resistant to gas that may endanger functions (sulfur dioxide (SO2), hydrogen sulfide (H2S))
Air pressure (operation): 70 kPa ... 108 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 66 kPa ... 108 kPa (up to 3500m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (storage/transport): 75 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
Air clearances and creepage distances
Air clearances and creepage distances: in accordance with IEC 60664-1
MountingMounting position: any
Technical Specs
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00150.pdf

Application_note_00183.pdf

Application_note_00111.pdf

Application_note_00110.pdf

Application_note_00042.pdf

Approvals_00916.pdf

Approvals_00917.pdf

Approvals_01112.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Manual_00083.pdf

Manufacturer_declaration_01375.pdf

Manufacturer_declaration_03289.pdf

Manufacturer_declaration_06723.pdf

Package_slip_00656.pdf