PHOENIX CONTACT 1199765
PHOENIX CONTACTNot available

SAC-4P- 1,0-PUR/M12FRS PE SH - Power cable

Power cable, 4-position, free cable end, on Socket angled M12, coding: S, cable length: 1 m, for AC current up to 12A/690V
Product Code: 1199765
Partner cod.: 1199765
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Product propertiesProduct type: Power cable
Number of positions: 4
Application: Power supply
Shielded: yes
Coding: S
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Material specificationsFlammability rating according to UL 94: V0
Electrical propertiesNominal voltage UN: 690 VAC
Nominal current IN: 12 A
Protective circuit: unwired
ConnectorConnection 1
Type: free cable end
Connection 2
Type: Socket angled M12
Coding type: S (Power)
Cable/lineCable length: 1 m
PUR halogen-free orange shielded[PUR]
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/ef808ef38b10cb4a830a35021c4c1cdb/-S204x204-FJPG
UL AWM Style: 20234 / 10492 (80°C/1000 V)
Number of positions: 4
Shielded: yes
Cable type: PUR halogen-free orange shielded[PUR]
Conductor cross section: 4x 1.5 mm²
Wire diameter incl. insulation: ≤ 2.5 mm
External cable diameter: 9.7 mm ±0.3mm
Outer sheath, material: PUR
External sheath, color: orange RAL2003
Conductor material: Bare Cu litz wires
Material wire insulation: PP
Single wire, color: black 1, black 2, black 3, green/yellow
Thickness, insulation: 0.4 mm
Thickness, outer sheath: 1.2 mm
Overall twist: 4 wires optimally twisted
Max. conductor resistance: ≤ 13.3 Ω/km (at 20°C)
Insulation resistance: ≥ 10 MΩ*km (at 20°C)
Nominal voltage, cable: 1000 VAC
Test voltage: 4260 VAC (5 min.)
Minimum bending radius, fixed installation: 5 x D
Minimum bending radius, flexible installation: 7.5 x D
Max. bending cycles: 4000000
Torsion force: ± 25°/m
Halogen-free: according to VDE 0282-13 Appendix C
Flame resistance: in accordance with EN60332-1-2
in acc. to UL1581 VW1
According to CSA C 22.2 No. 210-05 FT1
Resistance to oil: in accordance with DINEN60811-2-1
According to DIN EN 50363-10-2
Other resistance: UV resistant
Low adhesion
Ambient temperature (operation): -40°C ... 90°C (cable, fixed installation)
-30°C ... 90°C (Cable, flexible installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65 (without preloading, as additional test in accordance with IEC 60529)
IP67
Standards and regulationsStandard designation: M12 connector
Standards/specifications: IEC 61076-2-111
Technical Specs
ECLASSECLASS-11.0: 27060311
ECLASS-12.0: 27060311
ECLASS-13.0: 27060327
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600