Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1234232
PHOENIX CONTACTNot available

NEARFI D ETH B - Inductive coupler

NearFi, base coupler for contactless real-time Ethernet transmission in the centimeter range, 100Mbps, full duplex, M12 connection technology, IP65 type of protection. A remote coupler is required for operation.
Product Code: 1234232
Partner cod.: 1234232
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Inductive coupler
Application: Ethernet
MTTF: 239 Years (SN29500 standard, temperature25°C, operating cycle21%)
155 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
81 Years (SN29500 standard, temperature40°C, operating cycle100%)
Insulation characteristics
Overvoltage category: II
Pollution degree: 1
Electrical propertiesMaximum power dissipation for nominal condition: 3.72 W
Supply
Supply voltage range: 19 VDC ... 30 VDC
Typical current consumption: 155 mA (at 24VDC, at 25°C)
Inrush current: ≤ 0.25 A (20ms at 24VDC, without remote coupler)
Protective circuit: Transient protection, polarity protection
Connection dataSupply
Connection method: M12 connector (A-coded)
InterfacesData: Ethernet interface, 100Base-T(X) in accordance with IEEE802.3
Transmission speed: 100 Mbps
Connection method: M12 female, D-coded
No. of channels: 1
Transmission length: 100 m (shielded twisted pair)
Transmission medium: Copper
Inductive
Switch-on time: < 450 ms (ETH Full Duplex operating mode)
Range: min. 0 mm
typ. 20 mm (at65°C)
typ. 40 mm (at 25°C)
Wireless modules that can be connected: 1 (Remote coupler)
Wireless
Wireless modules that can be connected: 1 (Remote coupler)
Frequency: 60 GHz
Frequency range: 57 GHz ... 64 GHz (Data transmission)
Transmission power: < 10 mW (EIRP)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d36c7f3f40c2e14cb6c5418cfc6d323f/-S204x204-FJPG
Width: 80 mm
Height: 86 mm
Depth: 39 mm
Material specificationsMaterial: PBT
Die-cast zinc
Flammability rating according to UL 94: V0
Impact strength: IK06
Cable/lineOther resistance: Resistant to welding splashes
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65
Impact strength: IK06
Ambient temperature (operation): -20°C ... 65°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: 2000 m
Permissible humidity (operation): 10 % ... 95 %
Permissible humidity (storage/transport): 10 % ... 95 %
Air pressure (operation): 80 kPa ... 108 kPa (up to 2000m above sea level)
Air pressure (storage/transport): 66 kPa ... 108 kPa (up to 3500m above sea level)
ApprovalsCE
Certificate: CE-compliant
Wireless approval, Europe
Note: RED 2014/53/EU
Wireless approval Japan, MIC
Identification: 006-001056
KC approval for South Korea
Certificate: R-R-PCK-1234232
EMC dataElectromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Conducted noise emission: EN55032 Class A, industrial applications
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 4 kV (Test Level 2)
Discharge in air: ± 8 kV (Test Level 3)
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz (Test Level 3)
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2 kV (Test Level 3 - asymmetrical)
Output: ± 2 kV (Test Level 3 - asymmetrical)
Signal: ± 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV (Test Level 1 - symmetrical)
± 1 kV (Test Level 2 - asymmetrical)
Output: ± 1 kV (Test Level 2 - asymmetrical)
Signal: ± 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical)
Comments: Criterion A
Voltage: 10 V (80%amplitude modulation with 1kHz)
Emitted interference
Standards/regulations: EN55016-2-3
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: Yes
Other resistance: Resistant to welding splashes
Standards/regulations: EN60204-1 (PELV)
Standard designation: Protective extra-low voltage
MountingMounting type: Wall mounting
Assembly instructions: Observe derating
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27040701
ECLASS-12.0: 27040701
ECLASS-13.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00133.pdf

Application_note_00134.pdf

Approvals_00042.pdf

Approvals_00043.pdf

Approvals_01557.pdf

Approvals_01921.pdf

Approvals_01924.pdf

Data_sheet_01009.pdf

Manufacturer_declaration_03251.pdf

Manufacturer_declaration_05539.pdf

Package_slip_01696.pdf

Technical_drawing_10598.pdf

Various_00005.pdf