Industrial Automation
AXL E PN DI8 DO8 EF M12 6M-L - Digital module


Dimensions | Dimensional drawing: https://caas.phoenixcontact.com/caas/v1/stable/media/39804/full/b1500?format=jpg Width: 60 mm Height: 212 mm Depth: 30.2 mm |
Notes | Note on application Note on application: Only for industrial use |
Material specifications | Housing material: Zinc die-cast |
Interfaces | PROFINET Number of interfaces: 2 Connection method: M12 connector (D-coded) Note on the connection method: Push-pull fast connection according to IEC 61076-2-010 or screw connection according to IEC 61076-2-101 Number of positions: 4 Transmission speed: 100 Mbps (with auto negotiation) System-specific protocols: PROFINET protocols LLDP PROFINET protocols MRP client PROFINET protocols DCP PROFINET protocols DCE/RPC Protocols supported: HTTP SNMP v1 |
System properties | PROFINET Device function: PROFINET device Update rate: 1 ms Conformance Class: C (IRT switch) Supported functions: FSU < 600 ms I&M functions Device ID: 0181hex Vendor ID: 00B0hex |
Input data | Digital: Input name: Digital inputs Description of the input: EN 61131-2 types 1 and 3 Number of inputs: 8 Cable length: max. 30 m (to the sensor) Connection method: M12 connector (A-coded) Note on the connection method: Push-pull fast connection according to IEC 61076-2-010 or screw connection according to IEC 61076-2-101 Connection technology: 4-conductor Input voltage range "0" signal: 0 V ... 5 V DC Input voltage range "1" signal: 11 V DC ... 30 V DC Nominal input voltage UIN: 24 V DC Nominal input current at UIN: typ. 2.5 mA Sensor current per channel: max. 2 A (from US) Total sensor current: max. 2 A (per device) Input filter time: 3000 õs 1000 õs (Default) < 100 õs (Filter disabled) Protective circuit: Reverse polarity protection; yes Short-circuit protection; yes Overload protection; yes |
Output data | Digital: Output name: Digital outputs Connection method: M12 connector (A-coded) Note on the connection method: Push-pull fast connection according to IEC 61076-2-010 or screw connection according to IEC 61076-2-101 Connection technology: 3-conductor Number of outputs: 8 Protective circuit: Overload protection; yes Short-circuit protection; yes Output voltage: 24 V DC Limitation of the voltage induced on circuit interruption: -2 V ... -1 V Output current: 2 A (per output) Nominal output voltage: 24 V DC (from UA) Output voltage range: min. UA - 1 V ... max. UA Load min.: 10 ké Output voltage when switched off: max. 1 V Output current when switched off: max. 300 õA Nominal load, inductive: 48 VA (1.2 H, 12 é, at nominal voltage, utilization category DC-13) Nominal load, ohmic: 48 W (12 é, at nominal voltage) Switching frequency: max. 1 per second (with inductive load) Reverse voltage resistance to short pulses: no Behavior with overload: Shutdown with automatic restart Behavior with inductive overload: Output can be destroyed Signal delay: max. 100 õs (when switched on) max. 100 õs (when switched off, with at least 50 mA load current) Overcurrent shut-down: min. 2.2 A Output current with ground connection interrupt when switched off: < 1 mA |
Product properties | Product type: I/O component Product family: Axioline E Type: Stand-Alone Data management status Article revision: 00 Insulation characteristics Pollution degree: 2 (IEC 60664-1, EN 60664-1) |
Electrical properties | Supply: Sensors Designation: Supply of the logic and sensors (US) Connection method: M12 connector (L-coded) Note on the connection method: Screw connection in accordance with IEC 61076-2-111 Number of positions: 4 Supply voltage: 24 V DC Supply voltage range: 18 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption: typ. 65 mA max. 16 A Protection: max. 16 A Supply: Actuators Designation: Supply of actuators (UA) Connection method: M12 connector (L-coded) Note on the connection method: Screw connection in accordance with IEC 61076-2-111 Number of positions: 4 Supply voltage: 24 V DC (Nominal voltage) Supply voltage range: 18 V DC ... 30 V DC (including all tolerances, including ripple) Current consumption: typ. 50 mA max. 16 A Protection: max. 16 A Electrical isolation/isolation of the voltage ranges Test voltage: 24 V supply (logic and sensor supply US) / Ethernet interface 1: 1500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (logic and sensor supply US) / Ethernet interface 2: 1500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (logic and sensor supply US) / functional ground: 660 V AC, 50 Hz, 1 min. Test voltage: Ethernet interface 1 / functional ground: 1500 V AC, 50 Hz, 1 min. Test voltage: Ethernet interface 2 / functional ground: 1500 V AC, 50 Hz, 1 min. Test voltage: Ethernet interface 1 / Ethernet interface 2: 1500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply UA) / 24 V supply (logic and sensor supply US): 660 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply UA) / Ethernet interface 1: 1500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply UA) / Ethernet interface 2: 1500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (actuator supply UA) / functional ground: 660 V AC, 50 Hz, 1 min. |
Connection data | Connection method: M12 connector Tightening torque: 0.4 Nm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25 °C ... 70 °C Degree of protection: IP65/IP67/IP69 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000 m above sea level) Ambient temperature (storage/transport): -25 °C ... 85 °C Permissible humidity (operation): 5 % ... 95 % Permissible humidity (storage/transport): 5 % ... 95 % |
Standards and regulations | Protection class: III (IEC 61140, EN 61140, VDE 0140-1) |