PHOENIX CONTACT 1301402
PHOENIX CONTACTNot available

PSR-ME20-3NO-1NC-24DC-SC - Safety relays

Safety relay for emergency stops, safety doors, and light grids up to SIL2, Cat.3, PLd, 1- or 2-channel operation, automatic or manual, monitored start, 3enabling current paths, 1signaling current path, US=24VDC, plug-in screw terminal block
Product Code: 1301402
Partner cod.: 1301402
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Set comprises: 1301404 PSR-ME20-3NO-1NC-24DC-SC-SET35
Application: Emergency stop
Safety door
Light grid
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Times
Typical response time: 200 ms (automatic start)
200 ms (manual, monitored start)
Typ. starting time with Us: 200 ms (when controlled via A1)
Typical release time: 25 ms (on demand via the sensor circuit)
60 ms (on demand via A1)
Restart time: < 1 s (Boot time)
Recovery time: < 500 ms (following demand of the safety function)
Electrical propertiesMaximum power dissipation for nominal condition: 16.6 W (US=26.4V, IL²=72A², PTotalmax=2.2W+14.4W)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: Basic insulation 4kV between all output current paths
Basic insulation 4kV between all output current paths/logic paths and housing
Safe isolation, reinforced insulation 6kV between 250Vload current paths and 24Vlogic paths
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 24 VDC -15% / +10%
Rated control supply current IS: typ. 70 mA (at US)
Power consumption at US: typ. 1.68 W
Inrush current: < 5.2 A (typically with US, Δt=2ms)
Filter time: 5 ms (in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal; Suppressor diode
Input dataGeneral
Rated control supply current IS: typ. 70 mA (at US)
Digital: Sensor circuit (S10, S12, S22)
Description of the input: safety-related sensor inputs
Number of inputs: 3
Input voltage range "0" signal: 0 VDC ... 5 VDC (S10, S12)
Input voltage range "1" signal: 20.4 V ... 26.4 V
Input current range "0" signal: 0 mA ... 2 mA
Inrush current: < 100 mA (typically with US at S10/S12)
> -100 mA (typically with US at S22)
Filter time: 1 ms (Test pulse width of low test pulses)
1 s (Test pulse rate for low test pulse)
No brightness test pulses / high test pulses permitted.
Concurrence: ∞
Max. permissible overall conductor resistance: 50 Ω
Protective circuit: Suppressor diode
Current consumption: 38 mA (typically with US at S10/S12)
-38 mA (typically with US at S22)
Digital: Start circuit (S34, S35)
Description of the input: non-safety-related
Number of inputs: 2
Input voltage range "1" signal: 20.4 V ... 26.4 V
Inrush current: < 7 mA (Typically with US at S34)
< 8 mA (Typically with US at S35)
Filter time: No test pulses permitted
Max. permissible overall conductor resistance: 50 Ω
Protective circuit: Suppressor diode
Current consumption: 2 mA (Typically with US at S34)
3 mA (Typically with US at S35)
Output dataRelay: Enabling current paths (13/14, 23/24, 33/34)
Output description: 2 N/O contacts each in series, safety-related, floating
Number of outputs: 3
Contact switching type: 3 enabling current paths
Contact material: AgSnO2
Switching voltage: min. 10 V AC/DC
max. 250 VAC
Switching capacity: min. 100 mW
Inrush current: min. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 5 A (AC15)
6 A (DC13)
Limiting continuous current: 6 A (Observe derating and load limit curve)
Sq. Total current: 72 A2 (observe derating)
Switching frequency: max. 0.5 Hz
Mechanical service life: 10x 106 cycles
Output fuse: 10 A gL/gG
4 A gL/gG (for low-demand applications)
Relay: Signaling current path (41/42)
Output description: 2 N/C contacts parallel, non-safety-related, floating
Number of outputs: 1
Contact switching type: 2NC parallel
Contact material: AgSnO2
Switching voltage: min. 10 V AC/DC
max. 250 VAC
Switching capacity: min. 100 mW
Inrush current: min. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 3 A (AC15)
2 A (DC13)
Limiting continuous current: 6 A
Sq. Total current: 36 A2
Switching frequency: max. 0.5 Hz
Mechanical service life: 10x 106 cycles
Output fuse: 6 A gL/gG
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.5 Nm ... 0.6 Nm
SignalingStatus display: 2 x green LEDs
Operating voltage display: 1 x green LED
DimensionsWidth: 22.5 mm
Height: 112.2 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 3
Performance level (PL): d
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 2
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 2
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 2
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsCE
Identification: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: DINEN60947-1
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Screw connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00816.pdf

Approvals_00817.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Data_sheet_01043.pdf

Manufacturer_declaration_01477.pdf

Manufacturer_declaration_02849.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_06921.pdf

Package_slip_01983.pdf

Technical_drawing_10862.pdf