Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1337225
PHOENIX CONTACT 1337225
PHOENIX CONTACTNot available

AXL SE PD8/8 24V/GND - Potential distributors

Axioline SmartElements, Potential distribution module, 24VDC, GND, degree of protection: IP20
Product Code: 1337225
Partner cod.: 1337225
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
InterfacesSmartÂElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartÂElement.
System propertiesModule
ID code (hex): none
Process data channel: 0 bit
Input address area: 0 Byte (All systems except PROFIBUS)
1 Byte (PROFIBUS)
Output address area: 0 Byte
Required parameter data: 1 Byte
Required configuration data: 6 Byte
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartÂElements
Mounting position: See the system in which the SmartÂElement is used.
Insulation characteristics
Overvoltage category: II (IEC 60664-1, ENÂ60664-1)
Pollution degree: 2 (IEC 60664-1, ENÂ60664-1)
Electrical propertiesPotentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VÂDC (using card edge connectors)
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 4 A
Current consumption: min. 9 mA (without connected peripherals)
Power consumption: max. 120 W (of which 1.06ÂW constitute internal losses)
min. 173 mW
Protective circuit: Surge protection; See the system in which the SmartÂElement is used.
Reverse polarity protection; Polarity protection diode
Short-circuit/overload protection; electronic fuse (for terminal points 0 ... 7, 4ÂA)
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O): 500 VÂAC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24ÂV supply (I/O) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂSmartÂElements” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂSmartÂElements” user manual.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
MountingMounting type: Smart Element slot
Mounting position: See the system in which the SmartÂElement is used.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Data_sheet_01115.pdf

Manual_00045.pdf

Manufacturer_declaration_04057.pdf

Manufacturer_declaration_04071.pdf

Manufacturer_declaration_04371.pdf

Manufacturer_declaration_06961.pdf

Product_information_00033.pdf

Product_information_00120.pdf

Technical_drawing_11357.pdf