Industrial Automation
Notes | General: Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties | Product type: Sensor/actuator cable Number of positions: 5 Application: Railway applications No. of cable outlets: 1 Shielded: yes Coding: A Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Material specifications | Material of grip body: PA 6.6 Contact material: CuSn Contact surface material: Ni/Au Contact carrier material: PA 6.6 Material for screw connection: Zinc die-cast, nickel-plated |
Electrical properties | Contact resistance: ⤠5 mé Insulation resistance: ⥠100 Mé Nominal voltage UN: 48 VAC 60 VDC Nominal current IN: 4 A Protective circuit: unwired |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠100 |
Signaling | Status display: No Status display present: No |
Connection data | Conductor connection Tightening torque: 0.4 Nm (M12 connector) |
Connector | Connection 1 Type: Plug straight M12 SPEEDCON Number of positions: 5 Coding type: A Locking type: SPEEDCON Connection 2 Type: free cable end |
Cable/line | Cable length: 5 m Shielded black RADOX Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/608d9dbe6b37f2479e194b75b2c85728/-S204x204-FJPG Cable weight: 70 kg/km Number of positions: 5 Shielded: yes Cable type: Shielded black RADOX®[28R] Conductor structure signal line: 19x 0.18 mm AWG signal line: 20 Conductor cross section: 5x 0.5 mm² Wire diameter incl. insulation: 1.43 mm External cable diameter: 6.2 mm ±0.3mm Outer sheath, material: PE-X External sheath, color: black Conductor material: Tin-plated Cu litz wires Material wire insulation: PE-X Single wire, color: white 1, white 2, white 3, white 4, white 5 Overall twist: 5 cores, twisted Max. conductor resistance: ⤠40.1 é/km Nominal voltage, cable: 600 VAC (Core-ground, U0) 1000 VAC (Core-ground, U) ⤠720 VAC (core-ground) ⤠1200 VAC (Core-ground, Um) ⤠900 VDC (Core-ground, V0) ⤠1500 VDC (Line-line) Test voltage: 3500 VAC (50Hz, 5min.) 8400 VDC (50Hz, 5min.) Minimum bending radius, fixed installation: 3 x D Minimum bending radius, flexible installation: 4 x D Halogen-free: in accordance with EN 50267-2-1 Flame resistance: EN60332-1-2 EN50266 EN60332-3-25 NFC32-070, 2.1 NFC32-070, 2.2 UL1685, 12 (FT4) in accordance with ISO6722-1 5.22 (UN ECE-R 118.01) Fume corrosiveness: EN50267-2-2 Fume toxicity: BS6853 B.1 EN50305, 9.2 Concentration of fumes: BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) Resistance to oil: according to IRM 902, 72 h at 100°C Fire protection in rail vehicles: BS6853 (Category Ia, Ib, II) GM/RT2130 (Category Ia, Ib, II) EN45545 (Risk level HL1 - HL3) DIN5510 (Fire protection level 1, 2, 3, 4) NFF16-101 (Category A1, A2, B) NFF16-101 (Class C/F0) NFPA130 UNICEI11170 (Risk level LR1 - LR4) Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C Ambient temperature (operation): -50°C ... 120°C (cable, fixed installation) -25°C ... 90°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 Ambient temperature (operation): -40°C ... 85°C (Plug / socket) |
Standards and regulations | M12 Standard designation: M12 connector Shock, vibration Standards/specifications: IEC 61076-2-101 EN50155 |
Description other products