PHOENIX CONTACT 1408853
PHOENIX CONTACTNot available

SAC-4P- 5,0-PUR/M12FRS PE - Power cable

Power cable, 4-position halogen-free, free cable end, on Socket angled M12, coding: S, cable length: 5 m, for AC current up to 12A/690V
Product Code: 1408853
Partner cod.: 1408853
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Power cable
Number of positions: 4
Application: Power supply
No. of cable outlets: 1
Shielded: no
Coding: S
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Material specificationsFlammability rating according to UL 94: V0
Material of grip body: PP
Contact material: CuZn
Contact surface material: Ni/Au
Contact carrier material: PA
Material for screw connection: Zinc die-cast, nickel-plated
Electrical propertiesContact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Nominal voltage UN: 690 VAC
Nominal current IN: 12 A
Protective circuit: unwired
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: > 100
ConnectorConnection 1
Type: free cable end
Connection 2
Type: Socket angled M12
Coding type: S (Power)
Cable/lineCable length: 5 m
PUR halogen-free black[PUR]
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9d3b59d7bf6a934fad3370ff72bf00ae/-S204x204-FJPG
Cable weight: 114 kg/km
UL AWM Style: 20234 / 10492 (80°C/1000 V)
Number of positions: 4
Shielded: no
Cable type: PUR halogen-free black[PUR]
Conductor cross section: 4x 1.5 mm²
Wire diameter incl. insulation: 2.45 mm ±0.05 mm
External cable diameter: 8.8 mm ±0.25mm
Outer sheath, material: PUR
External sheath, color: black-gray RAL 7021
Conductor material: Bare Cu litz wires
Material wire insulation: PP
Single wire, color: black 1, black 2, black 3, green/yellow
Thickness, insulation: ≥ 0.36 mm
Thickness, outer sheath: approx. 1.3 mm
Overall twist: 4 wires, twisted
Length of twist, overall twist: 93 mm
Max. conductor resistance: ≤ 13 Ω/km (at 20°C)
Insulation resistance: ≥ 1 GΩ*km (at 20°C)
Nominal voltage, cable: ≤ 1000 VAC
Test voltage: ≥ 10000 VAC (Spark test)
Minimum bending radius, fixed installation: 5 x D
Minimum bending radius, flexible installation: 10 x D
Max. bending cycles: 2000000
Halogen-free: in accordance with DINVDE0472 part815
in accordance with DINEN50267-2-1
Flame resistance: According to UL758/1581 (Cable Flame)
according to UL758/1581 FT1
According to DINEN60332-1-2
Resistance to oil: According to DIN EN 60811-2-1, 168 h at 100°C
According to UL 758, 168 h at 60°C
Other resistance: Hydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation): -50°C ... 80°C (cable, fixed installation)
-30°C ... 80°C (Cable, flexible installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65
IP67 (without preloading, as additional test in accordance with IEC 60529)
Ambient temperature (operation): -25°C ... 85°C (Plug / socket)
Standards and regulationsStandard designation: M12 connector
Standards/specifications: IEC 61076-2-111
Technical Specs
ECLASSECLASS-11.0: 27060311
ECLASS-12.0: 27060311
ECLASS-13.0: 27060327
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600
Description
Power cable, 4-position, PUR halogen-free, black-gray RAL 7021, free cable end, on Socket angled M12, coding: S, cable length: 5 m, for AC current up to 12 A/690 V
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_01392.pdf

Manufacturer_declaration_02203.pdf

Manufacturer_declaration_05517.pdf