Industrial Automation
VS-OE-OE-936-100,0 - Data cable
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | Product type: Data cable by the meter Sensor type: PROFINET Number of positions: 4 Application: Railway applications Shielded: yes |
Electrical properties | Transmission medium: Copper |
Interfaces | Signal type/category: PROFINET CAT5 (IEC 11801:2002), 100 Mbps |
Connector | Connection 1 Type: free cable end Connection 2 Type: free cable end |
Cable/line | Cable length: 100 m PROFINET RADOX Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/35eeeb11fbacdc4187dc972d16fa1966/-S204x204-FJPG Cable weight: 81 g/m Number of positions: 4 Shielded: yes Cable type: PROFINET RADOX® railway application CAT5 reinforced[936] Conductor structure: 1x4xAWG22/7, SF/TQ Signal speed: 66 c Conductor structure signal line: 7x 0.25 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Wire diameter incl. insulation: 1.95 mm External cable diameter: 7.25 mm ±0.3mm Outer sheath, material: PE-X External sheath, color: black RAL9005 Conductor material: silver-plated Cu litz wires Material wire insulation: PE-X Single wire, color: white-blue, orange-yellow Thickness, outer sheath: ⥠0.8 mm Overall twist: Star quad Optical shield covering: 100 % Max. conductor resistance: ⤠54.4 é/km Coupling resistance: 200.00 mé/m (f ⤠30 MHz) Wave impedance: 100 é ±5é (f = 100 MHz) Working capacitance: ⤠65 pF (Line-line) ⤠100 pF (Line-shield) Nominal voltage, cable: 300 VAC Test voltage: 2000 VAC (50 Hz, 5 minutes) Minimum bending radius, fixed installation: 6 x D Minimum bending radius, flexible installation: 10 x D Near end crosstalk attenuation (NEXT): 80 dB (with 1 MHz) 76 dB (at 4 ÃHz) 67 dB (at 10 MHz) 60 dB (at 31.5ÃHz) 56 dB (at 62.5ÃHz) 53 dB (at 100 MHz) Return attenuation (RL): 35 dB (at 4 ÃHz) 35 dB (at 10 MHz) 35 dB (at 31.5ÃHz) 33 dB (at 62.5ÃHz) 33 dB (at 100 MHz) Remote crosstalk attenuation (FEXT): 80 dB (with 1 MHz) 70 dB (at 4 ÃHz) 65 dB (at 10 MHz) 58 dB (at 31.5ÃHz) 59 dB (at 62.5ÃHz) 67 dB (at 100 MHz) Shield attenuation: 2 dB (with 1 MHz) 4 dB (at 4 ÃHz) 6.5 dB (at 10 MHz) 10.5 dB (at 31.5ÃHz) 14 dB (at 62.5ÃHz) 18 dB (at 100 MHz) 40 dB (30 MHz ⤠f ⤠100 MHz) Halogen-free: in accordance with EN 50267-2-1 Flame resistance: EN60332-1-2 EN50266 EN60332-3-25 NFC32-070, 2.1 NFC32-070, 2.2 UL1685, 12 (FT4) in accordance with ISO6722-1 5.22 (UN ECE-R 118.01) Fume corrosiveness: EN50267-2-2 Fume toxicity: BS6853 B.1 EN50305, 9.2 Concentration of fumes: BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) Resistance to oil: according to IRM 902, 72 h at 100°C Fire protection in rail vehicles: BS6853 (Category Ia, Ib, II) GM/RT2130 (Category Ia, Ib, II) EN45545 (Risk level HL1 - HL3) DIN5510 (Fire protection level 1, 2, 3, 4) NFF16-101 (Category A1, A2, B) NFF16-101 (Class C/F0) NFPA130 UNICEI11170 (Risk level LR1 - LR4) Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C Ambient temperature (operation): -50°C ... 90°C (cable, fixed installation) -40°C ... 90°C (Cable, flexible installation) |
ECLASS | ECLASS-11.0: 27061801 ECLASS-12.0: 27061801 ECLASS-13.0: 27061801 |
ETIM | ETIM 9.0: EC003249 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products