Industrial Automation
NBC-FSDBP/0,25-937/R4AQ - Network cable
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Mounting | Mounting type: Screw mounting |
Product properties | Type: M12 Product type: Circular connectors (device side) Sensor type: PROFINET Number of positions: 4 No. of cable outlets: 1 Shielded: yes Cable outlet: straight Insulation characteristics Overvoltage category: I Degree of pollution: 3 |
Material specifications | Flammability rating according to UL 94: V0 (RJ45 und M12) Outer sheath, material: PE-X Conductor material: silver-plated Cu litz wires |
Electrical properties | Rated voltage (III/3): 72 V (DC) Transmission medium: Copper Transmission characteristics (category): CAT5 (IEC 11801:2002) Transmission speed: 100 Mbps Wave impedance: 100 é |
Connector | Connection 1 Type: Plug straight M12 Number of positions: 4 Connection 2 Type: Plug straight RJ45 Number of positions: 4 |
Cable/line | Cable length: 0.25 m PROFINET RADOX Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/35eeeb11fbacdc4187dc972d16fa1966/-S204x204-FJPG Shielded: yes Cable weight: 70 kg/km Cable type: PROFINET RADOX® railway application CAT5 Cable type (abbreviation): 937 Signal type/category: PROFINET CAT5 (IEC 11801), 100 Mbps EtherCAT® CAT5 (IEC 11801), 100 Mbps Cable structure: 1x4xAWG22/7, SF/TQ External cable diameter: 6.6 mm ±0.4mm Outer sheath, material: PE-X External sheath, color: black RAL9005 Thickness, outer sheath: approx. 1 mm Conductor material: silver-plated Cu litz wires Conductor structure signal line: 7x 0.25 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Material wire insulation: Foamed PE Wire diameter incl. insulation: approx. 1.5 mm Single wire, color: white-blue, orange-yellow Overall twist: Star quad Shielding: Plastic-coated aluminum foil, tinned copper braided shield Nominal voltage, cable: 300 VAC Test voltage, cable: 2000 VAC (50 Hz, 5 minutes) Cable resistance: ⤠54.4 é/km Coupling resistance: 200.00 mé/m (f ⤠30 MHz) Wave impedance: 100 é ±5é (f = 100 MHz) Working capacitance: ⤠65 pF (Line-line) ⤠100 pF (Line-shield) Signal speed: 75 c Minimum bending radius, fixed installation: 6 x D Damping: 2 dB (with 1 MHz) 4.4 dB (at 4 ÃHz) 7.4 dB (at 10 MHz) 14 dB (at 31.5ÃHz) 20 dB (at 62.5ÃHz) 26 dB (at 100 MHz) Remote crosstalk attenuation (FEXT): 78 dB (with 1 MHz) 77 dB (at 4 ÃHz) 70 dB (at 10 MHz) 65 dB (at 31.5ÃHz) 56 dB (at 62.5ÃHz) 48 dB (at 100 MHz) Near end crosstalk attenuation (NEXT): 73 dB (with 1 MHz) 70 dB (at 4 ÃHz) 65 dB (at 10 MHz) 57 dB (at 31.5ÃHz) 52 dB (at 62.5ÃHz) 48 dB (at 100 MHz) Return attenuation (RL): 25 dB (at 4 ÃHz) 30 dB (at 10 MHz) 30 dB (at 31.5ÃHz) 30 dB (at 62.5ÃHz) 28 dB (at 100 MHz) Shield attenuation: 40 dB (30 MHz ⤠f ⤠100 MHz) Fire protection in rail vehicles: BS6853 (Category Ia, Ib, II) GM/RT2130 (Category Ia, Ib, II) EN45545 (Risk level HL1 - HL3) DIN5510 (Fire protection level 1, 2, 3, 4) NFF16-101 (Category A1, A2, B) NFF16-101 (Class C/F0) NFPA130 UNICEI11170 (Risk level LR1 - LR4) Halogen-free: in accordance with EN 50267-2-1 Resistance to oil: according to IRM 902, 72 h at 100°C Concentration of fumes: BS 6853 D.8.7 EN 61034-2 UL 1685, 12 (FT4) Fume toxicity: BS6853 B.1 EN50305, 9.2 Fume corrosiveness: EN50267-2-2 Flame resistance: EN60332-1-2 EN50266 EN60332-3-25 NFC32-070, 2.1 NFC32-070, 2.2 UL1685, 12 (FT4) in accordance with ISO6722-1 5.22 (UN ECE-R 118.01) Other resistance: Resistance to fuels according to IRM 903, 168 h at 70°C Ambient temperature (operation): -40°C ... 90°C (Cable, flexible installation) -50°C ... 90°C (cable, fixed installation) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 70°C (Plug / socket) |
Standards and regulations | Flame resistance: UL1685 (CSA FT 4) |
ECLASS | ECLASS-11.0: 27060307 ECLASS-12.0: 27060307 ECLASS-13.0: 27060307 |
ETIM | ETIM 9.0: EC001855 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products