Notes | General: only use flexible conductors with ferrules Connectors may be operated only when there is no load/voltage. For HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required. |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required |
Product properties | Product type: Modular contact insert Number of positions: 12 Connection profile: 12 Contact numbering: 1 - 12 Application: Signal Number of module slots: 1 No. of power contacts: 0 No. of control contacts: 12 Contact material type: turned Series: HC-M-12 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Connection data | Connection technology Connection technology: Push-in connection Conductor connection Conductor cross section: 0.14 mm² ... 1.5 mm² Connection cross section AWG: 26 ... 16 Stripping length of the individual wire: 8 mm |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/1f40c90f7ef82443b6db8adc591d42b4/-S204x204-FJPG Width: 34.1 mm Height: 36.3 mm Length: 14.6 mm Mechanical characteristics Contact diameter: 1.6 mm |
Electrical properties | Rated voltage (III/2) contacts: 400 V Rated voltage (III/3): 250 V Rated surge voltage (III/2): 4 kV Rated surge voltage (III/3): 4 kV Rated surge voltage: 4 kV Rated current: 10 A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠500 |
Material specifications | Flammability rating according to UL 94: V0 Contact material: Copper alloy Contact surface material: Ag Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C |
Standards and regulations | Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440217 ECLASS-12.0: 27440217 ECLASS-13.0: 27440217 |
ETIM | ETIM 8.0: EC000438 |
UNSPSC | UNSPSC 21.0: 39121400 |