SAC-4P-M12MS/15,0-960 VA - Bus system cable

Bus system cable, FOUNDATION Fieldbus (31.25 kbps), 3-position, shielded, Plug straight M12, coding: A, on free cable end, cable length: 15 m
Product Code: 1431209
Partner cod.: 1431209
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
NotesGeneral: Further products with variable cable type and variable cable length can be found in the accessories section
Product propertiesProduct type: Data cable preassembled
Sensor type: FOUNDATION Fieldbus
Number of positions: 3
Application: Process technology
No. of cable outlets: 1
Shielded: yes
Coding: A
Insulation characteristics
Overvoltage category: II
Degree of pollution: 3
InterfacesBus system: FOUNDATION Fieldbus
Signal type/category: FOUNDATION Fieldbus, 31.25 kbps
SignalingStatus display: No
Status display present: No
Electrical propertiesContact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Nominal voltage UN: 48 VAC
60 VDC
Nominal current IN: 4 A
Transmission medium: Copper
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: ≥ 100
Material specificationsFlammability rating according to UL 94: HB
Seal material: NBR
Connection dataPin assignment
Contact | Color (signal designation) | Contact (optional): 1 (Plug) | BU (DATA-)
2 (Plug) | OG (DATA+)
3 (Plug) | SR (shield)
ConnectorConnection 1
Type: Plug straight M12
Number of positions: 3
Coding type: A (Standard)
Material: CuSn (Contact)
Ni/Au (Contact surface)
TPU GF (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Stainless steel (Screw connection)
Ambient temperature (operation): -25°C ... 90°C
Connection 2
Type: free cable end
Cable/lineCable length: 15 m
FOUNDATION Fieldbus orange[960]
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/53fdd1e616df3741873337c2fd15c293/-S204x204-FJPG
Cable weight: 56.552 kg/km
Number of positions: 2
Shielded: yes
Cable type: FOUNDATION Fieldbus orange[960]
Conductor structure: 2xAWG18/7 + 1xAWG20/7
Signal speed: 0.66 c
Conductor structure signal line: 7x 0.40 mm
AWG signal line: 18
Conductor cross section: 2x 0.75 mm² (Signal line)
1x 0.5 mm² (Drain wire)
Wire diameter incl. insulation: 2.24 mm ±0.05 mm
External cable diameter: 7.5 mm ±0.25mm
Outer sheath, material: PVC
External sheath, color: orange RAL2003
Conductor material: Tin-plated Cu litz wires
Material wire insulation: PO (Signal line)
Single wire, color: blue, orange
Thickness, insulation: 0.5 mm
Thickness, outer sheath: 1 mm
Twisted pairs: 2 cores to the pair
Overall twist: One pair with one drain wire and fillers for core
Optical shield covering: 100 %
Max. conductor resistance: ≤ 19.35 Ω/km (Signal line)
26 Ω/km (shield)
Cable capacity: 147 pF/m (at 1 kHz, core/shield)
≤ 3.94 pF/m (capacitance unbalance)
Working capacitance: 78 nF (at 1 kHz)
Cable impedance: 100 Ω ±20% (At 31.25 kHz)
Nominal voltage, cable: 300 V
Smallest bending radius, fixed installation: 75 mm
Tensile strength: 260 N
Shield attenuation: 3 dB/km (at 39 kHz)
Flame resistance: UL1685 (CSA FT 4)
UL1685 (vertical tray)
UL1666 (riser)
Special properties: UL standards PLTC-ER and ITC
Ambient temperature (operation): -40°C ... 105°C (cable, fixed installation)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65
IP67
IP68
IP69K
Technical Specs
ECLASSECLASS-11.0: 27060307
ECLASS-12.0: 27060307
ECLASS-13.0: 27060307
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600