Industrial Automation
Notes | General: For HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required, CK1,6-ED... crimp contacts, crimp contacts not supplied as standard. Connectors may be operated only when there is no load/voltage. The use of guide pins (HC-CST) and sockets (HC-CBU) is recommended to prevent tip collision due to misalignment. |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required |
Product properties | Product type: Modular contact insert Number of positions: 42 Connection profile: 42 Contact numbering: 1 - 42 Application: Signal Number of module slots: 2 No. of power contacts: 0 No. of control contacts: 42 Contact material type: turned Series: HC-M-42 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Connection data | Connection technology Connection technology: Crimp connection Conductor connection Conductor cross section: 0.14 mm² ... 2.5 mm² Connection cross section AWG: 26 ... 14 Stripping length of the individual wire: 8 mm (6mm with 2.5mm²) |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/4ebe34da1b47194bafe6b2356802bb7a/-S204x204-FJPG Width: 33.9 mm Height: 33 mm Length: 29.3 mm Mechanical characteristics Contact diameter: 1.6 mm |
Electrical properties | Rated voltage (III/3): 150 V Rated surge voltage: 2.5 kV Rated current: 10 A |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠500 |
Material specifications | Flammability rating according to UL 94: V0 Contact material: Copper alloy Contact surface material: Ag (alternatively Au) Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C (including heating up of contacts) |
Standards and regulations | Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440217 ECLASS-12.0: 27440217 ECLASS-13.0: 27440217 |
ETIM | ETIM 9.0: EC000438 |