Industrial Automation
SACC-DSI-M 8MS-6CON-M 8/0,5 - Device connector, rear mounting
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Mounting | Mounting type: Rear mounting M8 x 1 With flat nut Assembly instructions: With flat nut Connection method: Individual wires |
Product properties | Product type: Circular connectors (device side) Number of positions: 6 No. of cable outlets: 1 Shielded: no Coding: A Thread type: M8 Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Material specifications | Flammability rating according to UL 94: HB Seal material: FKM Contact material: Cu alloy Contact surface material: Au Contact carrier material: PUR/PA 6.6 Material for screw connection: Brass, nickel-plated Conductor material: Tin-plated Cu litz wires |
Electrical properties | Rated surge voltage: 0.8 kV Contact resistance: ≤ 3 mΩ Insulation resistance: ≥ 100 MΩ Nominal voltage UN: 30 VAC 30 VDC Nominal current IN: 2 A Max. conductor resistance: 80 Ω/km |
Connection data | Conductor connection Connection method: Individual wires Contact connection type: Pin Conductor cross section: 0.14 mm² Tightening torque: 1 Nm 1.5 Nm |
Connector | Connection 1 Head design: Pin Head cable outlet: straight Head thread type: M8 |
Cable/line | Cable length: 0.5 m Cable type: PVC litz wire Wire diameter incl. insulation: 1.3 mm ±0.1mm Single wire, color: black, brown,blue, white, gray, pink Cable cross section: 0.14 mm² Conductor material: Tin-plated Cu litz wires Conductor structure signal line: 7x 0.16 mm AWG signal line: 24 Material wire insulation: PVC / UL Thickness, insulation: 0.38 mm Nominal voltage, cable: 300 V Test voltage, cable: 2000 VAC Cable resistance: ≥ 80 Ω/km Cable insulation resistance: ≥ 20 MΩ*km Ambient temperature (operation): -40°C ... 105°C (cable, fixed installation) -10°C ... 105°C (Cable, flexible installation) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP67 Ambient temperature (operation): -25°C ... 85°C (Plug) -40°C ... 105°C (cable, fixed installation) -10°C ... 105°C (Cable, flexible installation) |
Standards and regulations | M8 Standard designation: M8 connector Standards/specifications: IEC 61076-2-104 |
ECLASS | ECLASS-11.0: 27440102 ECLASS-12.0: 27440116 ECLASS-13.0: 27440116 |
ETIM | ETIM 9.0: EC002635 |
UNSPSC | UNSPSC 21.0: 39121400 |