Industrial Automation
Notes | General: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g.by using cable ties. Unused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories". |
Product properties | Product type: Distributor boxes with M8 to M12 slots Number of positions: 5 Application: External areas Number of slots: 8 Coding: A |
Material specifications | Material: Die-cast zinc PBT PUR Seal material O-ring: FPM Contact material: Cu alloy Contact surface material: gold-plated Contact carrier material: PA Material of contact, master cable side: CU alloy Material of the contact carrier on the master cable side: PA 6.6 V0 Material of contact surface, master cable side: gold-plated |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/43b565cd0c4f79489ac26fe35556ea7a/-S204x204-FJPG Width: 58 mm Height: 45 mm Length: 153 mm |
Connection data | Conductor connection Connection method: Pluggable screw connection Stripping length: 7 mm Conductor cross section Flexible signal line: 0.14 mm² ... 1.5 mm² Conductor cross section Flexible power supply: 0.14 mm² ... 1.5 mm² Connection cross section AWG Flexible signal line: 26 ... 16 Connection cross section AWG Flexible power supply: 26 ... 16 Tightening torque, cover screw: 0.35 Nm Tightening torque slot sensor/actuator cable: 0.4 Nm Pin assignment Slot/position = Wire color or connection: 1 / 4 (A)=1 / 4 1 / 2 (B)=1 / 2 2 / 4 (A)=2 / 4 2 / 2 (B)=2 / 2 3 / 4 (A)=3 / 4 3 / 2 (B)=3 / 2 4 / 4 (A)=4 / 4 4 / 2 (B)=4 / 2 5 / 4 (A)=5 / 4 5 / 2 (B)=5 / 2 6 / 4 (A)=6 / 4 6 / 2 (B)=6 / 2 7 / 4 (A)=7 / 4 7 / 2 (B)=7 / 2 8 / 4 (A)=8 / 4 8 / 2 (B)=8 / 2 1-8 / 1 (+ 120 V)=UN 1-8 / 3 (0 V)=0 V 1-8 / 5 (PE)=PE |
Signaling | Status display present: No |
Electrical properties | Max. operating voltage Umax: 135 V Nominal voltage UN: 120 VAC 120 VDC Rated current, total: 10 A 2x 8 A (For electrical isolation) Max. current carrying capacity per path: 2 A Current carrying capacity per slot: 4 A |
Cable/line | Sensor/actuator connection system: M12 socket Connection method: Pluggable screw connection External cable diameter: 7 mm ... 12 mm Stripping length (signal): 7 mm Tightening torque, cover screw: 0.35 Nm Tightening torque slot sensor/actuator cable: 0.4 Nm Tightening torque, union nut: 2.5 Nm |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 IP67 Ambient temperature (operation): -40°C ... 80°C |
ECLASS | ECLASS-11.0: 27440111 ECLASS-12.0: 27440111 ECLASS-13.0: 27440111 |
ETIM | ETIM 9.0: EC003558 |
UNSPSC | UNSPSC 21.0: 31251500 |