XPC 1,5/11-ST-3,5 BK - PCB connector

PCB connector, nominal cross section: 1.5 mm2, color: black, nominal current: 8 A, rated voltage (III/2): 160 V, contact surface: Tin, contact connection type: Socket, number of rows: 1, number of positions: 11, product range: XPC 1,5/..-ST, pitch: 3.5 mm, connection method: Push-X-connection, conductor/PCB connection direction: 0 °, locking clip: - without locking clip, plug-in system: COMBICON MC 1,5, locking: without, mounting: without, type of packaging: packed in cardboard
Product Code: 1464115
Partner cod.: 1464115
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct line: COMBICON Connectors S
Product type: PCB connector
Product family: XPC 1,5/..-ST
Number of positions: 11
Pitch: 3.5 mm
Number of rows: 1
Electrical propertiesNominal current IN: 8 A
Nominal voltage UN: 160 V
Degree of pollution: 3
Contact resistance: 2.2 mΩ
Rated voltage (III/3): 160 V
Rated surge voltage (III/3): 2.5 kV
Rated voltage (III/2): 160 V
Rated surge voltage (III/2): 2.5 kV
Rated voltage (II/2): 320 V
Rated surge voltage (II/2): 2.5 kV
Connection dataConnection technology
Connector system: COMBICON MC 1,5
Nominal cross section: 1.5 mm²
Contact connection type: Socket
Interlock
Locking type: without
Mounting flange: without
Conductor connection
Connection method: Push-X-connection
Conductor/PCB connection direction: 0°
Conductor cross section rigid: 0.34 mm² ... 1.5 mm²
Conductor cross section flexible: 0.5 mm² ... 1.5 mm²
Conductor cross section AWG: 20 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 0.75 mm²
Cylindrical gauge a x b / diameter: 2.4mmx1.5mm / -
Stripping length: 10 mm
Specifications for ferrules without insulating collar
recommended crimping tool: 1212034 CRIMPFOX 6
1213144 CRIMPFOX CENTRUS 6S
ferrules without insulating collar, according to DIN46228‑1: Cross section:0.5 mm²; Length: 8 mm ... 10 mm
Cross section:0.75 mm²; Length: 8 mm ... 10 mm
Cross section:1 mm²; Length: 8 mm ... 10 mm
Cross section:1.5 mm²; Length: 10 mm
Specifications for ferrules with insulating collar
recommended crimping tool: 1212034 CRIMPFOX 6
1213144 CRIMPFOX CENTRUS 6S
ferrules with insulating collar, according to DIN46228‑4: Cross section:0.25 mm²; Length: 8 mm
Cross section:0.34 mm²; Length: 8 mm ... 10 mm
Cross section:0.5 mm²; Length: 8 mm ... 10 mm
Cross section:0.75 mm²; Length: 10 mm
Material specificationsMaterial data - contact
Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material: Cu alloy
Surface characteristics: hot-dip tin-plated
Metal surface terminal point (top layer): Tin (4 - 8 µm Sn)
Metal surface contact area (top layer): Tin (4 - 8 µm Sn)
Material data - housing
Color (Housing): black (9005)
Insulating material: PA
Insulating material group: I
CTI according to IEC 60112: 600
Flammability rating according to UL 94: V0
Material data – actuating element
Color (Actuating element): orange (2003)
Insulating material: PBT
Insulating material group: I
CTI according to IEC 60112: 600
Flammability rating according to UL 94: V0
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e1234e2392bde14688da8fe58a63c0c9/-S204x204-FJPG
Pitch: 3.5 mm
Width [w]: 40.13 mm
Height [h]: 12.46 mm
Length [l]: 19.3 mm
NotesNotes on operation: In accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load.
Mechanical testsConductor connection
Specification: IEC 60999-1:1999-11
Result: Test passed
Test for conductor damage and slackening
Specification: IEC 60999-1:1999-11
Result: Test passed
Repeated connection and disconnection
Specification: IEC 60999-1:1999-11
Result: Test passed
Pull-out test
Specification: IEC 60999-1:1999-11
Conductor cross section/conductor type/tractive force setpoint/actual value: 0.34 mm² / solid / > 15 N
0.5 mm² / flexible / > 20 N
1.5 mm² / solid / > 40 N
1.5 mm² / flexible / > 40 N
Insertion and withdrawal forces
Result: Test passed
No. of cycles: 25
Insertion strength per pos. approx.: 8 N
Withdraw strength per pos. approx.: 5 N
Resistance of inscriptions
Specification: IEC 60068-2-70:1995-12
Result: Test passed
Polarization and coding
Specification: IEC 60512-13-5:2006-02
Result: Test passed
Visual inspection
Specification: IEC 60512-1-1:2002-02
Result: Test passed
Dimension check
Specification: IEC 60512-1-2:2002-02
Result: Test passed
Environmental and real-life conditionsVibration test
Specification: IEC 60068-2-6:2007-12
Frequency: 10 - 150 - 10 Hz
Sweep speed: 1octave/min
50m/s² (60.1Hz...150Hz)
Amplitude: 0.35mm (10Hz...60.1Hz)
Test duration per axis: 2.5 h
Durability test
Specification: IEC 60512-9-1:2010-03
Impulse withstand voltage at sea level: 2.95 kV
Contact resistance R1: 2.2 mΩ
Contact resistance R2: 2.1 mΩ
Insertion/withdrawal cycles: 25
Insulation resistance, neighboring positions: >5MΩ
Climatic test
Specification: ISO22479:2019-05
Corrosive stress: 0.2 dm3 SO2 on 300 dm3/40°C/1 cycle
Thermal stress: 105°C/168h
Power-frequency withstand voltage: 1.39 kV
Ambient conditions
Ambient temperature (operation): -40°C ... 105°C (dependent on the derating curve)
Ambient temperature (storage/transport): -40°C ... 70°C
Relative humidity (storage/transport): 30 % ... 70 %
Ambient temperature (assembly): -5°C ... 100°C
Electrical testsThermal test | Test group C
Specification: IEC 60512-5-1:2002-02
Tested number of positions: 16
Insulation resistance
Specification: IEC 60512-3-1:2002-02
Insulation resistance, neighboring positions: >5MΩ
Air clearances and creepage distances |
Specification: IEC 60664-1:2007-04
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 160 V
Rated surge voltage (III/3): 2.5 kV
minimum clearance value - non-homogenous field (III/3): 1.5 mm
minimum creepage distance (III/3): 2 mm
Rated insulation voltage (III/2): 160 V
Rated surge voltage (III/2): 2.5 kV
minimum clearance value - non-homogenous field (III/2): 1.5 mm
minimum creepage distance (III/2): 1.5 mm
Rated insulation voltage (II/2): 320 V
Rated surge voltage (II/2): 2.5 kV
minimum clearance value - non-homogenous field (II/2): 1.5 mm
minimum creepage distance (II/2): 1.6 mm
Packaging specificationsType of packaging: packed in cardboard
Technical Specs
ECLASSECLASS-11.0: 27460202
ECLASS-13.0: 27460202
ECLASS-12.0: 27460202
ETIMETIM 9.0: EC002638
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01755.pdf

Approvals_01920.pdf

Data_sheet_01488.pdf

Package_slip_02594.pdf

Technical_drawing_15869.pdf

Other products

Description other products