Industrial Automation
NBC-M12MSD/ 0,5-93B/M12MSD CMC - Network cable


Notes | General: This product corresponds to the PROFINET Cabling and Interconnection Technology Guideline for PROFINET regulations, version 2.00, order no: 2.252, Chapter 10.1 Cord Sets for Balanced Cabling Further products with variable cable type and variable cable length can be found in the accessories section CMC - Conductor marker carrier - PATG |
Product properties | Product type: Data cable preassembled Sensor type: PROFINET Number of positions: 4 Application: Standard No. of cable outlets: 1 Shielded: yes Coding: D Insulation characteristics Overvoltage category: II Degree of pollution: 3 |
Interfaces | Bus system: PROFINET Signal type/category: PROFINET CAT5 (IEC 11801), 100 Mbps EtherCATî CAT5 (IEC 11801), 100 Mbps |
Signaling | Status display: No Status display present: No |
Electrical properties | Nominal voltage UN: 48 VÃAC 60 VÃDC Nominal current IN: 4 A Transmission medium: Copper Transmission characteristics (category): CAT5 (IEC 11801:2002) |
Material specifications | Flammability rating according to UL 94: V0 |
Connector | Connection 1 Type: Plug straight M12 / IP67 Number of positions: 4 Coding type: D (Data) Handle color: black Material: CuSn (Contact) Ni/Au (Contact surface) PA (Contact carriers) TPU, hardly inflammable, self-extinguishing (Grip) Zinc die-cast, nickel-plated (Screw connection) FKM (Seal) Insertion/withdrawal cycles: ââ°¥ 100 100 Contact resistance: ââ°¤ 5 mé Insulation resistance: ââ°¥ 100 Mé Tightening torque: 0.4 Nm Degree of protection: IP67 Ambient temperature (operation): -25°C ... 90°C Connection 2 Type: Plug straight M12 / IP67 Number of positions: 4 Coding type: D (Data) Handle color: black Material: CuSn (Contact) Ni/Au (Contact surface) PA (Contact carriers) TPU, hardly inflammable, self-extinguishing (Grip) Zinc die-cast, nickel-plated (Screw connection) FKM (Seal) Insertion/withdrawal cycles: ââ°¥ 100 Contact resistance: ââ°¤ 5 mé Insulation resistance: ââ°¥ 100 Mé Tightening torque: 0.4 Nm Ambient temperature (operation): -25°C ... 90°C Degree of protection: IP67 |
Cable/line | Cable length: 0.5 m PROFINET PVC stranded CAT5Ã[93B] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9641ad6bfe7a694da352f4faa5bb90c4/-S204x204-FJPG Cable weight: 67 kg/km UL AWM Style: 21694 Number of positions: 4 Shielded: yes Cable type: PROFINET PVC stranded CAT5Ã[93B] Conductor structure: 1x4xAWG22/7, SF/TQ Signal runtime: 5.3 ns/m Signal speed: 0.66 c Conductor structure signal line: 7x 0.25 mm AWG signal line: 22 Conductor cross section: 4x 0.34 mm² Wire diameter incl. insulation: 1.55 mm External cable diameter: 6.5 mm ñ0.2Ãmm Outer sheath, material: PVC External sheath, color: green RAL 6018 Conductor material: Tin-plated Cu litz wires Material wire insulation: PE Single wire, color: white, yellow, blue, orange Thickness, outer sheath: approx. 0.9 mm Overall twist: Star quad Optical shield covering: 85 % Insulation resistance: ââ°¥ 500 Mé*km Coupling resistance: ââ°¤ 20.00 mé/m (at 10 MHz) Loop resistance: ââ°¤ 120.00 é/km Wave impedance: 100 é ñ15Ãé (at 100 MHz) Nominal voltage, cable: 600 V Test voltage Core/Core: 2000 V (50ÃHz, 1Ãmin.) Test voltage Core/Shield: 2000 V (50ÃHz, 1Ãmin.) Minimum bending radius, fixed installation: 3 x D Minimum bending radius, flexible installation: 7 x D Smallest bending radius, fixed installation: 20 mm Smallest bending radius, movable installation: 46 mm Near end crosstalk attenuation (NEXT): 80 dB (with 1 MHz) 76 dB (at 4 Ãà Hz) 70 dB (at 10 MHz) 65 dB (at 16 MHz) 63 dB (at 20ÃÃà Hz) 60 dB (at 31.25ÃÃà Hz) 55 dB (at 62.5ÃÃà Hz) 50 dB (at 100 MHz) Shield attenuation: 2.1 dB (with 1 MHz) 4 dB (at 4 Ãà Hz) 6.3 dB (at 10 MHz) 8 dB (at 16 MHz) 9 dB (at 20ÃÃà Hz) 11.4 dB (at 31.25ÃÃà Hz) 16.5 dB (at 62.5ÃÃà Hz) 21.3 dB (at 100 MHz) Flame resistance: according to ULÃ1685 (CSA FT 4) Resistance to oil: Resistant to oil to a limited extent Other resistance: UV resistant According to ULÃ1581, Section 1200 Ambient temperature (operation): -40°C ... 70°C (cable, fixed installation) -40°C ... 70°C (Cable, flexible installation) Ambient temperature (installation): -20°C ... 60°C |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 (M12 connector) IP67 (M12 connector) |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
Description other products