Industrial Automation
Notes | General: For HEAVYCON ADVANCE and HEAVYCON housing of type B16, crimp contacts: CK 1,6-ED... (not included in scope of supply) Connectors may be operated only when there is no load/voltage. It is imperative that guide pins (HC-CST) and sockets (HC-CBU) are used to prevent tip collision due to misalignment. This product replaces 1679537 HC-D 40-EBUC-R |
Mounting | Assembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required |
Product properties | Type: B16 B32 Product type: Contact insert with a fixed no. of positions Number of positions: 40 Note number of positions: 40+PE Connection profile: 40+PE Application: Signal Number of connections per position: 1 Contact material type: turned rolled Series: HC-D Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9553974bd383ec408acb9680d17cf385/-S204x204-FJPG Width: 34 mm Height: 36 mm Length: 83 mm Drill hole distance, horizontal: 77.5 mm Mechanical characteristics Contact diameter: 1.6 mm |
Connection data | Connection technology Connection technology: Crimp connection Number of connections per position: 1 Connection in acc. with standard: IEC / EN Conductor connection Conductor cross section: 0.14 mm² ... 2.5 mm² Connection cross section AWG: 26 ... 14 Tightening torque: 0.8 Nm ... 1.2 Nm (PE connection) 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) Stripping length of the individual wire: 8 mm (0.14mm²...1.5mm²) 6 mm (2.5mm²) |
Electrical properties | Rated voltage (III/3): 250 V Rated surge voltage: 4 kV Rated current: 10 A SCCR: 5 kA (UL 2237) |
Mechanical properties | Mechanical data Insertion/withdrawal cycles: ⥠500 |
Material specifications | Flammability rating according to UL 94: V0 Contact material: Copper alloy Contact surface material: Ag (alternatively Au) Contact carrier material: PC Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -40°C ... 125°C (including heating up of contacts) |
Standards and regulations | Constructional and testing regulations: DINVDE0627/86 DINVDE0110/02.79 DINVDE0110-1/04.97 IEC 60664-1, DINIEC 60512 IEC 60352 Tests: DINVDE0627/86 DINVDE0110/02.79 DINVDE0110-1/04.97 IEC 60664-1, DINIEC 60512 IEC 60352 Testing Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3) |
ECLASS | ECLASS-11.0: 27440205 ECLASS-12.0: 27440205 ECLASS-13.0: 27440205 |
ETIM | ETIM 9.0: EC000438 |
UNSPSC | UNSPSC 21.0: 39121500 |