Product properties | Product line: COMBICON Connectors L Product type: PCB hybrid connector Product family: LPCH 6/..+4-ST Number of positions: 8 Pitch: 7.62 mm Number of connections: 8 Number of rows: 1 Number of potentials: 8 |
Electrical properties | Nominal current IN: 41 A Nominal voltage UN: 1000 V Degree of pollution: 3 Contact resistance: 0.42 mé Rated voltage (III/3): 800 V Rated surge voltage (III/3): 8 kV Rated voltage (III/2): 1000 V Rated surge voltage (III/2): 8 kV Rated voltage (II/2): 1000 V Rated surge voltage (II/2): 6 kV |
Connection data | Connection technology Connector system: COMBICON PC 6 hybrid Nominal cross section: 6 mm² Contact connection type: Socket Interlock Locking type: without Mounting flange: without Conductor connection Power Connection method: Lever Push-in connection Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 0.75 mm² ... 10 mm² Conductor cross section flexible: 0.75 mm² ... 6 mm² Conductor cross section AWG: 18 ... 8 Conductor cross section flexible, with ferrule without plastic sleeve: 0.75 mm² ... 6 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.75 mm² ... 6 mm² Cylindrical gauge a x b / diameter: 4.3mmx4.0mm / 4.0mm Stripping length: 18 mm Conductor connection Signal Connection method: Push-in spring connection Connection direction of the conductor to plug-in direction: 0° Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm² Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1 mm² Cylindrical gauge a x b / diameter: 2.4mmx1.5mm / 1.5mm Stripping length: 10 mm |
Material specifications | Material data - contact Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 Contact material: Cu alloy Surface characteristics: Tin-plated Metal surface terminal point (top layer): Tin (4 - 8 µm Sn) Metal surface contact area (top layer): Tin (4 - 8 µm Sn) Material data - housing Color (Housing): green (6021) Insulating material: PA GF Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 Material data â actuating element Color (Actuating element): orange (2003) Insulating material: PA GF Insulating material group: I CTI according to IEC 60112: 600 Flammability rating according to UL 94: V0 |
Notes | Notes on operation: In accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load. |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e1234e2392bde14688da8fe58a63c0c9/-S204x204-FJPG Pitch: 7.62 mm Width [w]: 40.3 mm Height [h]: 35.65 mm Length [l]: 48 mm |
Mechanical tests | Conductor connection Specification: IEC 60999-1:1999-11 Result: Test passed Test for conductor damage and slackening Specification: IEC 60999-1:1999-11 Result: Test passed Test for conductor damage and slackening â Specification: IEC 60999-1:1999-11 Result: Test passed Repeated connection and disconnection Specification: IEC 60999-1:1999-11 Result: Test passed Pull-out test Specification: IEC 60999-1:1999-11 Conductor cross section/conductor type/tractive force setpoint/actual value: 0.75 mm² / solid / > 30 N 0.75 mm² / flexible / > 30 N 10 mm² / solid / > 90 N 6 mm² / flexible / > 80 N Pull-out test â Specification: IEC 60999-1:1999-11 Conductor cross section/conductor type/tractive force setpoint/actual value: 0.2 mm² / solid / > 10 N 0.2 mm² / flexible / > 10 N 1.5 mm² / solid / > 40 N 1.5 mm² / flexible / > 40 N Insertion and withdrawal forces Result: Test passed No. of cycles: 25 Insertion strength per pos. approx.: 7 N Withdraw strength per pos. approx.: 4 N Contact holder in insert Specification: IEC 60512-15-1:2008-05 Contact holder in insert Requirements >20 N: Test passed Resistance of inscriptions Specification: IEC 60068-2-70:1995-12 Result: Test passed Polarization and coding Specification: IEC 60512-13-5:2006-02 Result: Test passed Visual inspection Specification: IEC 60512-1-1:2002-02 Result: Test passed Dimension check Specification: IEC 60512-1-2:2002-02 Result: Test passed |
Electrical tests | Thermal test | Test group C Specification: IEC 60512-5-1:2002-02 Tested number of positions: 4 Insulation resistance Specification: IEC 60512-3-1:2002-02 Insulation resistance, neighboring positions: >5Mé Temperature cycles Specification: IEC 60999-1:1999-11 Result: Test passed Air clearances and creepage distances | Power Specification: IEC 60664-1:2007-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 800 V Rated surge voltage (III/3): 8 kV minimum clearance value - non-homogenous field (III/3): 8 mm minimum creepage distance (III/3): 10 mm Rated insulation voltage (III/2): 1000 V Rated surge voltage (III/2): 8 kV minimum clearance value - non-homogenous field (III/2): 8 mm minimum creepage distance (III/2): 8 mm Rated insulation voltage (II/2): 1000 V Rated surge voltage (II/2): 6 kV minimum clearance value - non-homogenous field (II/2): 5.5 mm minimum creepage distance (II/2): 5.5 mm Air clearances and creepage distances | Signal Specification: IEC 60664-1:2007-04 Insulating material group: I Comparative tracking index (IEC 60112): CTI 600 Rated insulation voltage (III/3): 160 V Rated surge voltage (III/3): 2.5 kV minimum clearance value - non-homogenous field (III/3): 1.5 mm minimum creepage distance (III/3): 2 mm Rated insulation voltage (III/2): 160 V Rated surge voltage (III/2): 2.5 kV minimum clearance value - non-homogenous field (III/2): 1.5 mm minimum creepage distance (III/2): 1.5 mm Rated insulation voltage (II/2): 320 V Rated surge voltage (II/2): 2.5 kV minimum clearance value - non-homogenous field (II/2): 1.5 mm minimum creepage distance (II/2): 1.6 mm |
Environmental and real-life conditions | Vibration test Specification: IEC 60068-2-6:2007-12 Frequency: 10 - 150 - 10 Hz Sweep speed: 1octave/min 5g (60.1Hz...150Hz) Amplitude: 0.35mm (10Hz...60.1Hz) Test duration per axis: 2.5 h Durability test Specification: IEC 60512-9-1:2010-03 Impulse withstand voltage at sea level: 7.3 kV Contact resistance R1: 0.42 mé Contact resistance R2: 0.46 mé Insertion/withdrawal cycles: 25 Insulation resistance, neighboring positions: >5Mé Climatic test Specification: ISO6988:1985-02 Corrosive stress: 0.2 dm3 SO2 on 300 dm3/40°C/1 cycle Thermal stress: 100°C/168h Power-frequency withstand voltage: 3.31 kV Ambient conditions Ambient temperature (operation): -40°C ... 105°C (dependent on the derating curve) Ambient temperature (storage/transport): -40°C ... 70°C Relative humidity (storage/transport): 30 % ... 70 % Ambient temperature (assembly): -5°C ... 100°C |
Packaging specifications | Type of packaging: packed in cardboard |
ECLASS | ECLASS-11.0: 27460302 ECLASS-12.0: 27460302 ECLASS-13.0: 27460302 |
ETIM | ETIM 9.0: EC002638 |
UNSPSC | UNSPSC 21.0: 39121400 |