PHOENIX CONTACT 2304924
PHOENIX CONTACTNot available

FLK 50/2FLK20/EZ-DR/ 400/DV - Cable

Round cable set; controller: Emerson Delta V; connection 1: IDC/FLK socket strip (2x 20-position); connection 2: IDC/FLK socket strip (1x 50-position); cable length: 4 m
Product Code: 2304924
Partner cod.: 2304924
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: System cable
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP00
Degree of protection (Installation location): ≥ IP54 (Installation location)
Ambient temperature (operation): -40°C ... 70°C (fixed installation)
-10°C ... 70°C (flexible installation)
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m
Electrical propertiesOperating voltage (AC): ≤ 30 VAC
Operating voltage (DC): ≤ 60 VDC
Nominal operating mode: 100% operating factor
Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
Supported controller EMERSON DeltaV
Suitable I/O card: VE4001S2T2B5
VE4002S1T2B6
Cable/lineCable length: 4 m
40X0.14[PVC]
UL AWM Style: 2464/1061
Number of positions: 40
Shielded: no
Cable type: 40X0.14[PVC]
Conductor type: Round cable set
Conductor structure signal line: 7x 0.16 mm
AWG signal line: 26
Conductor cross section: 40x 0.14 mm²
Wire diameter incl. insulation: 1 mm ±0.03mm
External cable diameter: 9.9 mm ±0.4mm
Outer sheath, material: Semi-rigid PVC
External sheath, color: gray
Conductor material: Tin-plated Cu litz wires
Cable resistance: ≤ 145 Ω/km (20°C)
Insulation resistance: ≥ 20 MΩ*km (20°C)
Smallest bending radius, fixed installation: 82 mm
Smallest bending radius, movable installation: 155 mm
Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter)
Halogen-free: no
Flame resistance: IEC 60332-1-2 (raw cable)
VDE0842, Part332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
ULVW-1
CSA FT-1
Resistance to oil: can withstand occasional splashes (raw cable)
Connection dataConnection 1
Connection in acc. with standard: based on IEC 60603-13
Connection method: IDC/FLK socket strip
Number of connections: 2
Number of positions: 20
Insertion/withdrawal cycles: > 50
Pitch: 2.54 mm
Connection 2
Connection in acc. with standard: based on IEC 60603-13
Connection method: IDC/FLK socket strip
Number of connections: 1
Number of positions: 50
Insertion/withdrawal cycles: > 50
Pitch: 2.54 mm
NotesGeneral: For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Technical Specs
ECLASSECLASS-11.0: 27242220
ECLASS-12.0: 27242220
ECLASS-13.0: 27242220
ETIMETIM 9.0: EC000237
UNSPSCUNSPSC 21.0: 26121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00005.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Manufacturer_declaration_01145.pdf

Manufacturer_declaration_01818.pdf

Product_information_00033.pdf

Product_information_00638.pdf

Technical_drawing_37161.pdf