PHOENIX CONTACT 2311108
PHOENIX CONTACTNot available

UM-KS50/32-MR/21/ADV551/SO207 - Relay Module

32-channel output relay module (1 N/O contact, optionally non-isolated) with spring-cage connection, fuse (2 AT), and 50-pos. system connection. Suitable for the Yokogawa ADV 551 and ADV 561 cards.
Product Code: 2311108
Partner cod.: 2311108
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Interface module
No. of channels: 32
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics: Air clearances and creepage distances, input/output
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 2
Insulation characteristics: Air and creepage distances, output/output
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNo. of channels: 32
Air clearances and creepage distances, input/output
Rated insulation voltage: 300 V
Rated surge voltage: 6 kV (1.2/50 μs)
Air and creepage distances, output/output
Rated insulation voltage: 260 V
Rated surge voltage: 4 kV (1.2/50 μs)
Supported controller YOKOGAWA CS3000 CentumVP
Suitable I/O card: ADV551
ADV561
Supported controller YOKOGAWA STARDOM
Suitable I/O card: NFDV551
NFDV561
Input dataNominal input voltage UN: 24 VDC
Input voltage range in reference to UN: 0.8 ... 1.1
Input voltage range: 19.2 VDC ... 26.4 VDC
Typical input current at UN: 9 mA (per channel)
Protective circuit: Damping diode, polarity protection; Damping diode, polarity protection diode
Reverse polarity protection; Polarity protection diode
Operating voltage display: Green LED
Status display/channel: Yellow LED
Output dataSwitching
Contact switching type: 1 N/O contact
Type of switch contact: Single contact
Contact material: AgSnO
Maximum switching voltage: 230 VAC
Limiting continuous current: 2 A (Per channel, plug-in fuse (IEC 6012-3/IV, 2AT); for 100% ED 1A per channel)
Maximum inrush current: 8 A (Supply, (V1+, V2+), pluggable fuse (UL 248-14, 250 V, 8AT))
Min. switching current: 100 mA
Interrupting rating (ohmic load) max.: 48 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
500 VA (for 250 V AC)
Connection dataField level
Connection method: Spring-cage connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 14
Controller level
Connection method: Yokogawa KS-compatible
Number of connections: 1
Number of positions: 50
Note: Usable system cables: Phoenix Contact YUC50, Yokogawa AKB331
Tightening torque: 0.5 Nm
SignalingStatus display present: Yes
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/192f7863e811f3428a99e8a5acd432d3/-S204x204-FJPG
Width: 267 mm
Height: 127.5 mm
Depth: 56.5 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP00
Degree of protection (Installation location): ≥ IP54 (Installation location)
Ambient temperature (operation): -20°C ... 50°C
Ambient temperature (storage/transport): -20°C ... 70°C
Altitude: ≤ 2000 m
Standards and regulationsAir clearances and creepage distances, input/output
Standards/regulations: EN61010-2-201
Air and creepage distances, output/output
Standards/regulations: EN61010-2-201
MountingMounting type: DIN rail mounting
Mounting position: any
NotesGeneral: Observe the maximum switching capacity of the relays used
Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
The outputs are not suitable for switching different line conductors. The sum of the switching voltages used for adjacent outputs must not exceed the rated insulation voltage value
The necessary requirements for insulation (basic insulation or reinforced insulation) from adjacent modules (in DIN-rail direction) must be realized by applying suitable measures (e.g., partition plates).
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Technical Specs
ECLASSECLASS-11.0: 27141152
ECLASS-12.0: 27141152
ECLASS-13.0: 27141152
ETIMETIM 9.0: EC002780
UNSPSCUNSPSC 21.0: 39121400
Description
32-channel output relay module (1 N/O contact, optionally non-isolated) with spring-cage connection, fuse (2 AT), and 50-pos. system connection. Suitable for the Yokogawa ADV 551 and ADV 561 cards.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00005.pdf

Manufacturer_declaration_00627.pdf

Manufacturer_declaration_02316.pdf

Manufacturer_declaration_14212.pdf

Product_information_00033.pdf

Product_information_00190.pdf

Technical_drawing_37243.pdf