Industrial Automation
Product properties | Product type: System cable |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP00 Degree of protection (Installation location): ⥠IP54 (Installation location) Ambient temperature (operation): -40°C ... 70°C (fixed installation) -10°C ... 70°C (flexible installation) Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m |
Electrical properties | Operating voltage (AC): ⤠30 VAC Operating voltage (DC): ⤠60 VDC Nominal operating mode: 100% operating factor Current (Per path, 50°C): ⤠1 A (Uncoiled, see derating) Current (Per path, 70°C): ⤠0.6 A (Uncoiled, see derating) |
Cable/line | Cable length: 3 m 16X0.14[PVC] Number of positions: 16 Shielded: no Cable type: 16X0.14[PVC] Conductor type: Round cable set Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Conductor cross section: 16x 0.14 mm² Wire diameter incl. insulation: 1 mm ±0.03mm External cable diameter: 6.8 mm ±0.4mm Outer sheath, material: Semi-rigid PVC External sheath, color: gray Conductor material: Tin-plated Cu litz wires Cable resistance: ⤠145 é/km (20°C) Insulation resistance: ⥠20 Mé*km (20°C) Smallest bending radius, fixed installation: 58 mm Smallest bending radius, movable installation: 108 mm Max. bending cycles: 5000 (at a radius of ⥠15x outside diameter) Halogen-free: no Flame resistance: IEC 60332-1-2 (raw cable) VDE0842, Part332-1-2 (raw cable) IEC 60332-3-22 (raw cable) ULVW-1 CSA FT-1 Resistance to oil: can withstand occasional splashes (raw cable) color code IDC/FLK16 (1): () = black IDC/FLK16 (2): () = brown IDC/FLK16 (3): () = red IDC/FLK16 (4): () = orange IDC/FLK16 (5): () = yellow IDC/FLK16 (6): () = green IDC/FLK16 (7): () = blue IDC/FLK16 (8): () = violet IDC/FLK16 (9): () = gray IDC/FLK16 (10): () = white IDC/FLK16 (11): () = white-black IDC/FLK16 (12): () = white-brown IDC/FLK16 (13): () = white-red IDC/FLK16 (14): () = white-orange IDC/FLK16 (15): () = white-yellow IDC/FLK16 (16): () = white-green |
Connection data | Connection 1 Connection method: Single wires Stripping length (Sheath): ï» 150 mm Number of positions: 16 Note: The wires are marked and fitted with ferrules Connection 2 Connection in acc. with standard: based on IEC 60603-13 Connection method: IDC/FLK socket strip Number of connections: 1 Number of positions: 16 Insertion/withdrawal cycles: > 50 Pitch: 2.54 mm |
Notes | General: For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
ECLASS | ECLASS-11.0: 27242220 ECLASS-12.0: 27242220 ECLASS-13.0: 27242220 |
ETIM | ETIM 9.0: EC000237 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products