Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2320911
PHOENIX CONTACTNot available

QUINT-PS/1AC/24DC/10/CO - Power supply, with protective coating

Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input:1-phase, output: 24 VDC / 10 A
Product Code: 2320911
Partner cod.: 2320911
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Input dataAC operation
Nominal input voltage range: 100 VAC ... 240 VAC
110 VDC ... 250 VDC
Input voltage range: 85 VAC ... 264 VAC
90 VDC ... 410 VDC +5% (UL 508: ≤ 250 V DC)
Input voltage range AC: 85 VAC ... 264 VAC
Input voltage range DC: 90 VDC ... 410 VDC +5% (UL 508: ≤ 300 V DC)
Electric strength, max.: 300 VAC
Voltage type of supply voltage: AC/DC
Inrush current: < 15 A
Inrush current integral (I2t): < 1.5 A2s
AC frequency range: 50 Hz ... 60 Hz
Mains buffering time: typ. 36 ms (120VAC)
typ. 36 ms (230 V AC)
Current consumption: 4 A (100VAC)
1.7 A (240VAC)
2.2 A (120VAC)
1.3 A (230 V AC)
2.5 A (110VDC)
1.2 A (220 VDC)
3.4 A (110VDC)
1.5 A (250VDC)
Nominal power consumption: 303 VA
Protective circuit: Transient surge protection; Varistor, gas-filled surge arrester
Typical response time: < 0.15 s
Input fuse: 10 A (slow-blow, internal)
Permissible backup fuse: B10 B16
Recommended breaker for input protection: 10 A ... 20 A (AC: Characteristics B, C, D, K)
Discharge current to PE: < 3.5 mA
Output dataEfficiency: typ. 92.5 % (230 V AC)
Nominal output voltage: 24 VDC ±1%
Setting range of the output voltage (USet): 18 VDC ... 29.5 VDC (> 24VDC, constant capacity)
Nominal output current (IN): 10 A (-25°C...60°C, UOUT =24VDC)
POWER BOOST (IBoost): 15 A (-25°C...40°C permanent, UOUT = 24VDC )
Selective Fuse Breaking (ISFB): 60 A (12ms)
Magnetic circuit breaker tripping: B2 / B4 / B6 / C2 / C4
Derating: 60°C ... 70°C (2.5%/K)
Feedback voltage resistance: ≤ 35 VDC
Protection against overvoltage at the output (OVP): ≤ 32 VDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 50 mVPP (with nominal values)
Output power: 240 W
Maximum no-load power dissipation: 9.1 W
Power loss nominal load max.: 22 W
Rise time: < 0.05 s (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Signal: DC OK active
Output description: UOUT > 0.9 x UN: High signal
Switching voltage range: 18 VDC ... 24 VDC
Maximum inrush current: 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Signal: DC OK floating
Output description: Relay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage: 30 VAC
24 VDC
Maximum inrush current: 0.5 A (ATEX/IECEx: Ohmic loads only)
1 A (ATEX/IECEx: Ohmic loads only)
Continuous load current: ≤ 1 A
Signal: POWER BOOST, active
Output description: IOUT < IN: High signal
Switching voltage range: 18 VDC ... 24 VDC
Output voltage: + 24 VDC
Maximum inrush current: 20 mA (short-circuit-proof)
Continuous load current: ≤ 20 mA
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Signal
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 16
Conductor cross section AWG max.: 12
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Active switching output
Relay contact
Signal output: DC OK active
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
IOUT < IN: LED ON
LED flashing
Color: green
Signal output: DC OK floating
Status display: UOUT > 0.9 x UN: "DC OK" LED green
Note on status display: UOUT < 0.9 x UN: Flashing "DC OK" LED
LED flashing
Color: green
Signal output: POWER BOOST, active
Status display: IOUT > IN: LED "BOOST" yellow
Color: yellow
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE: 500 VDC (routine test)
Insulation voltage input / PE: 3.5 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: QUINT POWER
MTBF (IEC 61709, SN 29500): > 940000 h (25°C)
> 530000 h (40°C)
> 230000 h (60°C)
Insulation characteristics
Protection class: I
Degree of pollution: 2
DimensionsWidth: 60 mm
Height: 130 mm
Depth: 125 mm
Installation dimensions
Installation distance right/left: 5 mm / 5 mm
Installation distance top/bottom: 50 mm / 50 mm
Alternative assembly
Width: 122 mm
Height: 130 mm
Depth: 63 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: PN ≥50%, 5mm horizontally, 15mm next to active components, 50mm vertically
alignable: PN <50%, 0mm horizontally, 40mm vertically top, 20 mm vertically bottom
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: yes
Material specificationsHousing material: Metal
Hood version: Galvanized sheet steel, free from chrome (VI)
Side element version: Aluminum
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C (>60°C Derating: 2,5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 5000 m
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): 100 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: EN50121-4
EN50121-3-2
HART FSK Physical Layer Test Specification Compliance: Output voltage UOut compliant
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: IEC 61010-2-201(SELV)
Explosive atmosphere: EN60079-15 (Zone2)
Standard - Equipment safety: BG (design tested)
Standard – Safety extra-low voltage: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation: IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1
Noxious gas test: ISA-S71.04-1985 G3 Harsh Group A
Approval - requirement of the semiconductor industry with regard to mains voltage dips: SEMI F47-0706 Compliance Certificate
DeviceNet approval: DeviceNet™ Power Supply Conformance Tested
Overvoltage category
EN 61010-1: II(≤5000m)
EN 62477-1: III(≤2000m)
ApprovalsCSA: CAN/CSA-C22.2 No.60950-1-07
CSA-C22.2 No.107.1-01
Shipbuilding approval: DNVGL(EMCB),ABS, LR, RINA, NK, BV
SIQ: BG (type approved)
UL approvals: UL/C-UL listed UL508
UL/C-UL Recognized UL60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
DeviceNet approval: DeviceNet™ Power Supply Conformance Tested
Conformity/Approvals
ATEX: II3GExecnCIICT4Gc
TÜV 11 ATEX 079480 X
INMETRO: DNV190189X
IECEx: ExecnCIICT4Gc
IECEx TUN 11.0007X
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 55011 (EN 55022)
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2 GHz
2 GHz ... 3 GHz
Test field strength: 20 V/m (Test Level 3)
10 V/m (Test Level 3)
10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Emitted interference
Standards/regulations: EN61000-6-3
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Technical Specs
ECLASSECLASS-11.0: 27040701
ECLASS-12.0: 27040701
ECLASS-13.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00041.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00148.pdf

Approvals_00177.pdf

Approvals_00179.pdf

Approvals_00182.pdf

Approvals_00184.pdf

Approvals_00249.pdf

Approvals_01177.pdf

Approvals_01302.pdf

Approvals_01445.pdf

Approvals_01904.pdf

Approvals_01905.pdf

Data_sheet_03126.pdf

Manufacturer_declaration_04622.pdf

Manufacturer_declaration_04623.pdf

Manufacturer_declaration_14322.pdf

Package_slip_02062.pdf

Technical_drawing_37418.pdf

Various_00080.pdf

Various_00006.pdf