Industrial Automation
AXL F DO32/1 1F - Digital module


Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG Width: 53.6 mm Height: 126.1 mm Depth: 54 mm Note on dimensions: The depth applies when a THÃ35-7.5 DIN rail is used (in accordance with ENÃ60715). |
Interfaces | AxiolineÃFÃlocal bus Number of interfaces: 2 Connection method: Bus base module Transmission speed: 100 Mbps |
System properties | Module Input address area: 0 Byte Output address area: 4 Byte Required parameter data: 1 Byte Required configuration data: 6 Byte |
Output data | Digital Output name: Digital outputs Connection method: Push-in connection Connection technology: 1-conductor Number of outputs: 32 Protective circuit: Short-circuit protection, overload protection of the outputs; electronic Output voltage: 24 VÃDC Limitation of the voltage induced on circuit interruption: -32.8 V ... -15 V Maximum output current per module: 8 A (up to HWÃ04, provide external protection) 16 A (from HWÃ05, provide external protection) Nominal output voltage: 24 VÃDC Load min.: 10 ké Output voltage when switched off: max. 1 V Output current when switched off: max. 300 õA Nominal load, inductive: max. 12 VA (1.2 H, 48 é, with nominal voltage) Nominal load, lamp: max. 12 W (at nominal voltage) Nominal load, ohmic: max. 12 W (48 é, with nominal voltage) Switching frequency: max. 5500 per second (with ohmic load) max. 1 per second (with inductive load) max. 16 per second (with nominal lamp load) Reverse voltage resistance to short pulses: limited protection up to 0.5 A for 1 s Behavior with overload: Shutdown with automatic restart Behavior with inductive overload: Output can be destroyed Signal delay: max. 150 õs (when switched on) max. 200 õs (during switching off with ohmic nominal load) Overcurrent shut-down: as of 0.7 A Output current with ground connection interrupt when switched off: < 1 mA |
Product properties | Type: block modular Product type: I/O component Product family: AxiolineÃF Mounting position: any (no temperature derating) Scope of delivery: including bus base module and AxiolineÃF connectors Insulation characteristics Overvoltage category: II (IEC 60664-1, ENÃ60664-1) Pollution degree: 2 (IEC 60664-1, ENÃ60664-1) |
Electrical properties | Maximum power dissipation for nominal condition: 2.7 W Potentials: AxiolineÃF local bus supply (U Supply voltage: 5 VÃDC (via bus base module) Current draw: max. 120 mA (up to HW 04) max. 60 mA (from HW 05) Power consumption: max. 600 mW (up to HW 04) max. 300 mW (from HW 05) Potentials: Supply for digital output modules (U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Current draw: max. 8 A (up to HWÃ04, provide external protection) max. 16 A (from HWÃ05, provide external protection; if the total current of 8ÃA is exceeded, connect the supply at the power connector parallel via both terminal points.) Power consumption: max. 240 W (up to HWÃ04, of which 1.5ÃW constitute internal losses) max. 480 W (from HWÃ05, of which max. 2.4ÃW constitute internal losses) Protective circuit: Surge protection; electronic (35 V, 0.5 s) Reverse polarity protection; parallel diode; with external 5ÃA fuse (only for commissioning) Electrical isolation/isolation of the voltage ranges Test voltage: 5ÃV supply of the local bus (UBus) / 24ÃV supply (I/Os): 500 VÃAC, 50 Hz, 1 min. Test voltage: 5ÃV supply of the local bus (UBus) / functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24ÃV supply (I/O) / functional ground: 500 VÃAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: AxiolineÃF connector Note on the connection method: Please observe the information provided on conductor cross sections in the ââ¬Ã AxiolineÃF: system and installationâ⬠user manual. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm AxiolineÃF connector Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the ââ¬Ã AxiolineÃF: system and installationâ⬠user manual. Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) |
Mounting | Mounting type: DIN rail mounting Mounting position: any (no temperature derating) |
Description other products