Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2700525
PHOENIX CONTACT 2700525
PHOENIX CONTACTNot available

PSR-MC32-3NO-1NC-24-230UC-SP - Safety relays

Safety relay for emergency stop, safety doors and light grids up to SIL3, Cat.4, PLe, 1 or 2-channel operation, automatic or manual, monitored start, 3 enabling current paths, 1 signaling current path, US=24...230VAC/DC, pluggable Push-in terminal block
Product Code: 2700525
Partner cod.: 2700525
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRmini
Application: Emergency stop
Safety door
Solenoid switch
Transponder
Light grid
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/ENÂ61810-3
Times
Typical response time: < 150 ms (automatic start)
< 100 ms (manual, monitored start)
Typ. starting time with Us: < 200 ms (when controlled via A1)
Typical release time: < 20 ms (when actuation is via the sensor circuit)
Restart time: < 1 s
Recovery time: < 500 ms
Electrical propertiesMaximum power dissipation for nominal condition: 17.3 W (at IL²Ãƒ‚=Â72ÂA²)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VÂAC
Rated surge voltage/insulation: Basic insulation 4ÂkV between enabling current path (23/24) and enabling current path (33/34) and signaling current path (41/42)
Basic insulation 4ÂkV between all current paths and housing
Safe isolation, reinforced insulation 6ÂkV between all other circuits
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 24 V AC/DC ... 230 V AC/DC -15Â% / +10Â%
Rated control supply current IS: typ. 103 mA (24ÂVÂDC)
typ. 47 mA (48ÂVÂDC)
typ. 38 mA (110ÂVÂAC)
typ. 21 mA (230 VÂAC)
Power consumption at US: 2.7 W (with DC)
2.9 W (with AC)
Apparent power: typ. 5 VA (at US)
Inrush current: < 80 A (ΔtÂ=Â50µs at Us)
Filter time: 2 ms (at A1 in the event of voltage dips at Us)
Protective circuit: US: surge protection; 275 V varistor / 411 V suppressor diode
Input dataDigital: Sensor circuit (S10, S12, S13, S22)
Description of the input: safety-related sensor inputs
Number of inputs: 4
Input voltage range "0" signal: 0 VÂDC ... 5 VÂDC (for safe Off; at S10/S12/S13)
Input current range "0" signal: 0 mA ... 2 mA (for safe Off; at S10/S12/S13)
Inrush current: < 5 mA (with Us/Ix at S10/S12/S13)
> -5 mA (with Us/Ix to S22)
Filter time: max. 1.5 ms (to S10-S12; test pulse width; at 24ÂVÂDC)
7.5 ms (to S10-S12; test pulse rate; at 24ÂVÂDC)
Test pulse rateÂ=Â5ÂxÂTest pulse width
Concurrence: âˆÅ¾
Max. permissible overall conductor resistance: 150 Ω
Protective circuit: Inputs: protection against polarity reversal, surge protection; 38.6 V suppressor diode
Current consumption: < 5 mA (with Us/Ix at S10/S12/S13)
> -5 mA (with Us/Ix to S22)
Digital: Start circuit (S34, S35)
Description of the input: non-safety-related
Number of inputs: 2
Inrush current: < 10 mA (ΔtÂ=Â330Âms)
Max. permissible overall conductor resistance: 150 Ω
Protective circuit: Suppressor diode
Voltage at input/start and feedback circuit: 24 VÂDC -20Â%Â/Â+25Â%
Current consumption: typ. 2.5 mA (S34)
typ. 1 mA (S35)
Output dataRelay: Enabling current paths (13/14, 23/24, 33/34)
Output description: safety-related N/O contacts
Number of outputs: 3 (undelayed)
Contact switching type: 3 enabling current paths
Contact material: AgSnO2
Switching voltage: min. 5 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Switching capacity: min. 50 mW
Inrush current: min. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 5 A (24ÂV (DC13))
5 A (250ÂV (AC15))
Limiting continuous current: 6 A (observe derating)
Sq. Total current: 72 A2 (observe derating)
Switching frequency: max. 1 Hz
Mechanical service life: 10x 106 cycles
Interrupting rating (ohmic load) max.: 1500 VA (250 V AC, Ï„ = 0 ms)
For additional values, see load curve
Maximum interrupting rating (inductive load): 48 W (24ÂVÂDC, τÂ=Â40Âms)
40 W (48 V DC, Ï„ = 40 ms)
36 W (60 V DC, Ï„ = 40 ms)
35 W (110 V DC, Ï„ = 40 ms)
33 W (220 V DC, Ï„ = 40 ms)
1500 VA (250ÂVÂAC, τÂ=Â40Âms)
Output fuse: 6 A gL/gG
4 A gL/gG (for low-demand applications)
Relay: Signaling current path (41/42)
Output description: non-safety-related N/C contact
Number of outputs: 1 (undelayed)
Contact switching type: 1 signaling current path
Contact material: AgSnO2
Switching voltage: min. 5 V AC/DC
max. 250 V AC/DC
Switching capacity: min. 50 mW
Inrush current: min. 10 mA
max. 6 A
Limiting continuous current: 6 A
Switching frequency: 1 Hz
Mechanical service life: 10x 106 cycles
Output fuse: 6 A gL/gG
4 A gL/gG (for low-demand applications)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG: 24 ... 16
Stripping length: 8 mm
SignalingStatus display: 3 x green LED
Operating voltage display: 1 x green LED
DimensionsWidth: 22.5 mm
Height: 117.4 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENÂISOÂ13849
Category: 4 (5ÂAÂDC13; 5ÂAÂAC15; 8760Âswitching cycles/year)
Performance level (PL): e
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3
Safety data: ENÂIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -40°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10ÂHzÂ...Â150ÂHz, 2g
ApprovalsCE
Identification: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: ENÂ60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Push-in connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00885.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01906.pdf

Data_sheet_03220.pdf

Manufacturer_declaration_00795.pdf

Manufacturer_declaration_14476.pdf

Package_slip_01970.pdf

Technical_drawing_37624.pdf