Industrial Automation
IB IL TEMP 2 UTH-XC-PAC - Temperature module


Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8f49d2b498684640a945b59e148b2698/-S204x204-FJPG Width: 12.2 mm Height: 136.8 mm Depth: 71.5 mm Note on dimensions: Housing dimensions |
Interfaces | Inline local bus Number of interfaces: 2 Connection method: Inline data jumper Transmission speed: 500 kbps |
System properties | Module ID code (dec.): 127 ID code (hex): 7F Length code (hex): 02 Length code (dec): 02 Process data channel: 32 bit Input address area: 4 Byte Output address area: 4 Byte Register length: 32 bit Required parameter data: 6 Byte Required configuration data: 4 Byte |
Input data | Analog Input name: Analog UTH inputs Description of the input: Inputs for thermocouples or linear voltage Number of inputs: 2 (Thermocouples or linear voltage) Connection method: Inline connector Connection technology: 2-conductor Note regarding the connection technology: Shielded compensating line for TC with encapsulated sensors A/D conversion time: typ. 120 õs (per channel) Sensor types that can be used (TC): U, T, L, J, E, K, N, S, R, B, C, W, HK Measuring principle: Successive approximation Measured value representation: 16 bits (15 bits + sign bit) Process data update: max. 30 ms (For both channels) Protective circuit: Surge protection (TC channels); up to ñ40ÃV |
Product properties | Type: modular Product type: I/O component Product family: Inline Scope of delivery: including Inline connector and labeling field Operating mode: Process data operation with 2 words Diagnostics messages: Failure of the internal I/O supply I/O error message sent to the bus coupler Failure of or insufficient communications power UL I/O error message sent to the bus coupler I/O error Error message in the process data User error Error message in the process data |
Electrical properties | Potentials Power consumption: typ. 587 mW max. 882 mW Potentials: Communications power (U Supply voltage: 7.5 VÃDC (via voltage jumper) Current draw: max. 60 mA typ. 43 mA Potentials: Supply of analog modules (U Supply voltage: 24 VÃDC (via voltage jumper) Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple) Current draw: max. 18 mA typ. 11 mA Electrical isolation/isolation of the voltage ranges Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O): 500 VÃAC, 50 Hz, 1 min. Test voltage: 7.5ÃV supply (bus logic)/functional ground: 500 VÃAC, 50 Hz, 1 min. Test voltage: 24ÃV analog supply (analog I/O)/functional ground: 500 VÃAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: Inline connector Conductor connection Connection method: Spring-cage connection Conductor cross section rigid: 0.08 mm² ... 1.5 mm² Conductor cross section flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm Inline connector Connection method: Spring-cage connection Conductor cross section, rigid: 0.08 mm² ... 1.5 mm² Conductor cross section, flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 55°C (Standard) -40°C ... 70°C (Extended, see section ââ¬Ã Tested successfully: use under extreme ambient conditionsâ⬠in the data sheet.) Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 10 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) |
Mounting | Mounting type: DIN rail mounting |
Description other products