Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2701237
PHOENIX CONTACTNot available

AXL F AO8 XC 1F - Analog module

AxiolineF, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extremeconditions version, degree of protection: IP20, including bus base module and AxiolineF connectors
Product Code: 2701237
Partner cod.: 2701237
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 16 Byte
Output address area: 16 Byte
Required parameter data: 27 Byte
Required configuration data: 7 Byte
Output dataAnalog
Output name: Analog outputs
Connection method: Push-in connection
Connection technology: 2-conductor
Note regarding the connection technology: shielded, twisted pair
Number of outputs: 8
D/A conversion time: 5 µs
D/A converter resolution: 16 bit
Protective circuit: Short-circuit and overload protection; electronic
Transient protection; Suppressor diode
Data formats: IB IL, S7-compatible
Representation of output values: 16 bits (15 bits + sign)
Process data update: 300 µs
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current output: to 500 Ω
Voltage output signal: 0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output: > 2 kΩ
Permissible cable length: max. 250 m (Reference cable type LiYCY (TP) n*2*0.5mm²)
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (observe temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesPotentials
Power consumption: typ. 1.725 W (To UBus and UA, intrinsic power input, no load, output 0V, up to HW02)
typ. 1.4 W (To UBus and UA, intrinsic power input, no load, output 0V, as of HW03)
max. 6.29 W (To UBus and UA, 8 current channels, output 20mA, up to HW02)
max. 5.88 W (To UBus and UA, 8 current channels, output 20 mA, as of HW03)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 130 mA (up to HW02)
max. 50 mA (from HW 03)
typ. 105 mA (up to HW02)
typ. 40 mA (from HW 03)
Power consumption: max. 0.65 W (up to HW02)
max. 0.25 W (from HW 03)
typ. 0.525 W (up to HW02)
typ. 0.2 W (from HW 03)
Potentials: Supply for analog modules (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 235 mA (8 current channels, 20 mA output)
typ. 110 mA (8 voltage channels, 10V output)
Power consumption: max. 5.64 W (8 current channels, 20 mA output)
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; up to HW01: polarity protection diodefrom HW02: parallel diode; with external 5A fuse (for startup only)
Transient protection; Suppressor diode
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus)/analog outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: Analog outputs/functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C (Standard)
-40°C ... 70°C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (observe temperature derating)
Technical Specs
ECLASSECLASS-11.0: 27242601
ECLASS-12.0: 27242601
ECLASS-13.0: 27242601
ETIMETIM 9.0: EC001596
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01209.pdf

Approvals_01303.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01759.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Data_sheet_03260.pdf

Manual_00007.pdf

Manual_00006.pdf

Manufacturer_declaration_00781.pdf

Manufacturer_declaration_02283.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Manufacturer_declaration_14553.pdf

Package_slip_00688.pdf

Product_information_00033.pdf

Product_information_00289.pdf

Technical_drawing_37691.pdf

Various_00004.pdf