Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2702859
PHOENIX CONTACT 2702859
PHOENIX CONTACTNot available

AXL F SSDOR4/2 1F - Safety module

AxiolineF, Functional safety, Signal inputs: 2, Outputs OUT24V_0and OUT24V_1:2, Safe relay outputs:4 (floating), N/O contact, degree of protection: IP20
Product Code: 2702859
Partner cod.: 2702859
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/9bf47cad1f9a594387de8d805d9e0343/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: Housing dimensions
InterfacesAxiolineFlocal bus
Connection method: Bus base module
System propertiesModule
Input address area: 8 Byte
Output address area: 8 Byte
Required parameter data: 1 Byte
Required configuration data: 7 Byte
Input dataDigital
Input name: Signal inputs
Number of inputs: 2
Input voltage: Power supply from clock outputs UT1 and UT2
Nominal input current at UIN: typ. 3.2 mA
Output dataDigital
Output name: Outputs OUT24V_0and OUT24V_1
Number of outputs: 2
Nominal output voltage: Power supply from U0 or U1
Relay
Number of outputs: 4 (floating)
Contact switching type: N/O contact
Switching voltage: min. 12 V AC/DC
max. 30 V AC/DC
Switching current: min. 3 mA
max. 6 A (30VDC)
Switching capacity: min. 60 mW
Limiting continuous current: 6 A
Mechanical service life: 10x 106 cycles
Output fuse: 6 A gL/gG (See “Application examples” section)
Product propertiesType: modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any
Application: Functional safety
Operating mode: SafetyBridge
Insulation characteristics
Overvoltage category: II (IEC 60664-1)
Pollution degree: 2 (IEC 60664-1)
Electrical propertiesTransmission medium: Copper
Potentials
Protection: max. 500 mA slow-blow (for UI)
max. 6 A gL/gG ()
Protective circuit: Polarity reversal protection of the supply voltage; parallel protection against polarity reversal for a limited period of time
Surge voltage detection; at 31V
Undervoltage detection; at 17V
Surge protection of the supply voltage; electronic (35 V, 0.5 s)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 163 mA (at UBus 5VDC)
typ. 93 mA (at UBus 5VDC)
Potentials: Supply voltage U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30.2 VDC (including all tolerances, including ripple)
Current draw: max. 30 mA
typ. 10 mA (Power supply from UI with 30VDC, all inputs set)
Potentials: Feed-in U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 6 A
typ. 1.6 mA (Power supply from U0 with 30V DC, all inputs set without load)
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.5 mm² ... 1.5 mm²
Conductor cross section flexible: 0.5 mm² ... 1.5 mm²
Conductor cross section AWG: 20 ... 16
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor cross section, rigid: 0.5 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.5 mm² ... 1.5 mm²
Conductor cross section AWG: 20 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -35°C ... 60°C
Degree of protection: IP20
Degree of protection at installation location: min. IP54
Air pressure (operation): 70 kPa ... 108 kPa
Air pressure (storage/transport): 66 kPa ... 108 kPa
Ambient temperature (storage/transport): -40°C ... 85°C
Standards and regulationsProtection class: III (IEC 61140-1)
Air clearances and creepage distances
Air clearances and creepage distances: IEC 60664-1
MountingMounting type: DIN rail mounting
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 8.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00523.pdf

Approvals_01199.pdf

Approvals_01935.pdf

Certification_00317.pdf

Certification_00369.pdf

Manual_00194.pdf

Manufacturer_declaration_01376.pdf

Manufacturer_declaration_03283.pdf

Manufacturer_declaration_14736.pdf

Package_slip_00769.pdf

Technical_drawing_37887.pdf