PHOENIX CONTACT 2708575
PHOENIX CONTACTNot available

PSI-MOS-RS422/FO1300 E - FO converters

Fiber optic converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4 wire/ INTERBUS up to 2 Mbps, termination device with one fiber optic interface (SC duplex), 1300 nm, for fiberglass cable
Product Code: 2708575
Partner cod.: 2708575
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Media converter
MTTF: 891 Years (SN29500 standard, temperature25°C, operating cycle21%)
397 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
164 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 544 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
113 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Electrical propertiesElectrical isolation: VCC // RS-422
Maximum power dissipation for nominal condition: 2.75 W
Test voltage data interface/power supply: 1.5 kVrms (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 32 VDC
Nominal supply voltage: 24 VDC (in acc. with UL)
Typical current consumption: 110 mA (24VDC)
Max. current consumption: ≤ 2 A (For operation in a joining station, via the DIN rail connector)
Output dataSwitching
Output name: Relay output
Output description: Alarm output
Number of outputs: 1
Maximum switching voltage: 60 VDC
42 VAC
Limiting continuous current: 1 A
Connection dataSupply
Connection method: COMBICON plug-in screw terminal block
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesBit distortion, input: ± 35 % (permitted)
Bit distortion, output: < 6.25 %
Signal: INTERBUS
Transmission channels: 2 (1/1) RD, TD, full duplex
Data: optical FO
No. of channels: 1
Transmit capacity, minimum: -3.4 dBm (50/125μm, multimode fiberglass)
-4.7 dBm (62.5/125μm, multimode fiberglass)
-5.5 dBm (9/125μm, singlemode fiberglass)
Transmission length incl. 3 dB system reserve: 27 km (With F-G 50/125 0.7 dB/km at 1300 nm)
22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm)
45 km (With F-E 9/125 0,4 dB/km at 1300 nm)
Transmission protocol: Transparent to protocol for RS-422 interface
Connection method: SC duplex
Wavelength: 1300 nm
Minimum receiver sensitivity: -25.5 dBm (50/125µm)
-25.5 dBm (62,5/125 µm)
-26.5 dBm (9/125µm)
Maximum receiver sensitivity: 0 dBm
Transmission medium: Multi-mode fiberglass
Single-mode fiberglass
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Serial transmission speed: ≤ 2 Mbps
Connection method: Pluggable screw connection
Transmission length: ≤ 1000 m (depending on the data rate, with shielded, twisted data cable)
Termination resistor: 220 Ω
100 Ω
220 Ω
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 14
Min. AWG conductor cross section, flexible: 24
Single-wire/terminal point, rigid AWG max.: 14
Single-wire/terminal point, rigid AWG min.: 24
Transmission medium: Copper
File format/coding: UART (11 Bit, NRZ)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/2eee325507f9634ca62ca0c80ff27cd3/-S204x204-FJPG
Width: 35 mm
Height: 105 mm
Depth: 103 mm
Material specificationsMaterial: PA 6.6-FR
Cable/lineFO cable
Fiber types: 50/125 µm
9/125 µm
Fiberglass
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation): 30 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex nA nC IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: 508 Listed
508 Recognized
KC approval for South Korea
Certificate: MSIP-REI-PCK-2708575
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 55011
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV
Discharge in air: ± 8 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2 kV
Signal: ± 2 kV
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV
Signal: ± 1 kV
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55011
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19170411
ECLASS-12.0: 19170411
ECLASS-13.0: 19170411
ETIMETIM 9.0: EC001467
UNSPSCUNSPSC 21.0: 43201500
Description
Fiber optic converter with integrated optical diagnostics, alarm contact, for RS-422/RS-485 4 wire/ INTERBUS up to 2 Mbps, termination device with one fiber optic interface (SC duplex), 1300 nm, for fiberglass cable
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00156.pdf

Approvals_00121.pdf

Approvals_01268.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01763.pdf

Approvals_01936.pdf

Data_sheet_03408.pdf

Data_sheet_03077.pdf

Manufacturer_declaration_04646.pdf

Manufacturer_declaration_05546.pdf

Manufacturer_declaration_14828.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01843.pdf

Technical_drawing_38031.pdf