PHOENIX CONTACT 2723136
PHOENIX CONTACTNot available

IBS INBC METER - Installation remote bus cable

By the meter, Installation remote bus cable, INTERBUS, shielded, PUR, may green RAL 6017, 9-wire (3x2x0.22mm2+3x1mm2), color single wire: green-yellow, white-brown, gray-pink, red, blue, green/yellow, fixed installation
Product Code: 2723136
Partner cod.: 2723136
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Remote bus cable
Number of positions: 9
Electrical propertiesTransmission medium: Copper
Cable/lineNumber of positions: 9
Shielded: yes
Conductor structure: 3x2x0.22mm²+3x1mm²
Signal speed: 0.66 c
Conductor structure signal line: 7x 0.20 mm
Conductor cross section: 3x 2x 0.22 mm² (Data)
3x 1 mm² (Supply)
Wire diameter incl. insulation: 1 mm (Data)
1.7 mm (Supply)
External cable diameter: 7.7 mm +0.2mm
Outer sheath, material: PUR
External sheath, color: may green RAL 6017
Conductor material: Bare Cu litz wires
Material wire insulation: PE
Single wire, color: green-yellow, white-brown, gray-pink, red, blue, green/yellow
Twisted pairs: 2 cores to the pair
Overall twist: 3 pairs and 3 wires to form the core
Insulation resistance: ≥ 5 GΩ*km (Data)
≥ 5 GΩ*km (Supply)
Coupling resistance: < 250.00 mΩ/m (at 30 MHz)
Loop resistance: ≤ (Data)
≤ (Supply)
Wave impedance: 110 Ω ±20Ω (at 64kHz)
95 Ω ±15Ω (at >1MHz)
Cable capacity: ≤ 60 nF/km (At 800 Hz)
Nominal voltage, cable: 250 V (Peak value, not for high-power applications)
450 V (Supply)
Test voltage Core/Core: 1500 Vrms
Test voltage Core/Shield: 1000 Vrms
Minimum bending radius, fixed installation: 7.5 x D
Minimum bending radius, flexible installation: 15 x D
Near end crosstalk attenuation (NEXT): ≥ 61 dB (at 772kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20МHz)
Shield attenuation: ≤ 10 dB/km (at 256kHz)
≤ 25 dB/km (at 772kHz)
≤ 28 dB/km (with 1 MHz)
≤ 69 dB/km (at 4 МHz)
≤ 12 dB/km (at 10 MHz)
≤ 15.5 dB/km (at 16 MHz)
≤ 17.2 dB/km (at 20МHz)
Flame resistance: according to VDE0472, Part 804, test type B
according to IEC 60332-1
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-30°C ... 70°C (Cable, flexible installation)
Technical Specs
ECLASSECLASS-11.0: 27061801
ECLASS-12.0: 27061801
ECLASS-13.0: 27061801
ETIMETIM 9.0: EC003249
UNSPSCUNSPSC 21.0: 26121600