Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area Utilization restrictionâ CCCex note: Use in potentially explosive areas is not permitted in China. |
Product properties | Product type: Interface converter Application: RS-232 RS-422 RS-485 MTTF: 1654 Years (SN29500 standard, temperature25°C, operating cycle21%) 746 Years (SN29500 standard, temperature40°C, operating cycle34.25%) 310 Years (SN29500 standard, temperature40°C, operating cycle100%) MTBF: 10 Years (Telcordia standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day)) Insulation characteristics Pollution degree: 2 |
Electrical properties | Electrical isolation: VCC // V.24 (RS-232) // RS-485 Maximum power dissipation for nominal condition: 2.04 W Test voltage data interface/power supply: 1.5 kV AC Test voltage data interfaces: 1.5 kV AC Supply Supply voltage range: 18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block) Nominal supply voltage: 24 V AC/DC Typical current consumption: 85 mA (24VDC) Max. current consumption: 100 mA |
Connection data | Supply Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm² Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm² Conductor cross section, flexible [AWG]: 24 ... 12 Tightening torque: 0.56 Nm ... 0.79 Nm |
Interfaces | Interface: RS-232/-485 Bit distortion: ⤠5 % Bit delay: ⤠2.5 µs Signal: Modbus Transmission channels: 2 (1/1), RxD, TxD, full duplex Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN66259-1 Serial transmission speed: 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2kbps Connection method: D-SUB9 plug Pin assignment: DTE/DCE switchover via switch Transmission length: 15 m (shielded twisted pair) Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm² Max. AWG conductor cross section, flexible: 12 Min. AWG conductor cross section, flexible: 24 Protocols supported: transparent protocol Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 Serial transmission speed: 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps Connection method: Pluggable screw connection Transmission length: 1200 m (shielded twisted pair) Termination resistor: 390 é 150 é 390 é (Can be connected) Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm² Max. AWG conductor cross section, flexible: 13 Min. AWG conductor cross section, flexible: 24 Protocols supported: transparent protocol Data: RS-485 interface in acc. with EIA/TIA-485, DIN 66259-1 Serial transmission speed: 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps Connection method: Pluggable screw connection Transmission length: 1200 m (shielded twisted pair) Termination resistor: 390 é 150 é 390 é (Can be connected) Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm² Max. AWG conductor cross section, flexible: 14 Min. AWG conductor cross section, flexible: 24 Data direction switching: Automatic control or via RTS/CTS Protocols supported: transparent protocol |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d5d8fb589b189545a32006c46a180100/-S204x204-FJPG Width: 22.5 mm Height: 99 mm Depth: 114.5 mm |
Material specifications | Material: PA 6.6-FR |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (For restrictions, see the manufacturer's declaration for altitude operation) Permissible humidity (operation): 10 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant EAC Identification: EAC ATEX Identification: ï II 3 G Ex nA IIC T4 Gc Certificate: IBExU16ATEXB004 X Note: Please follow the special installation instructions in the documentation! IECEx Identification: Ex nA IIC T4 Gc Certificate: IECEx IBE 15.0034X UL, USA/Canada Identification: 508 Recognized Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, AEx nA IIC T4 Class I, Zone 2, Ex nA IIC T4 Gc X KC approval for South Korea Certificate: MSIP-REI-PCK-ME2744416 Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A Shipbuilding Identification: DNV GL DNV GL data Temperature: B Humidity: A Vibration: A EMC: B Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Noise immunity: EN 61000-6-2:2005 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Noise emission: EN 61000-6-4 Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV (Test Level 3) Discharge in air: ± 8 kV (Test Level 3) Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 26 MHz ... 3 GHz (Test Level 3) Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: ± 2.2 kV (Test Level 3) Signal: ± 2.2 kV (Test Level 3) Comments: Criterion B Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Input: ± 0.5 kV (DC supply) Signal: ± 1 kV (Data line, asymmetrical) Comments: Criterion B Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN55011 Comments: Class A, industrial applications Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. |
Mounting | Mounting type: DIN rail mounting |
ECLASS | ECLASS-11.0: 27242208 ECLASS-12.0: 27242208 ECLASS-13.0: 27242208 |
ETIM | ETIM 9.0: EC001423 |
UNSPSC | UNSPSC 21.0: 32151700 |