Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2744416
PHOENIX CONTACTAvailable

PSM-ME-RS232/RS485-P - Interface converter

Interface converter, for converting RS-232 (V.24) to RS-422 (V.11) and RS-485, with electrical isolation, 2 channels, rail-mountable
Product Code: 2744416
Partner cod.: 2744416
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Interface converter
Application: RS-232
RS-422
RS-485
MTTF: 1654 Years (SN29500 standard, temperature25°C, operating cycle21%)
746 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
310 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 10 Years (Telcordia standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day))
Insulation characteristics
Pollution degree: 2
Electrical propertiesElectrical isolation: VCC // V.24 (RS-232) // RS-485
Maximum power dissipation for nominal condition: 2.04 W
Test voltage data interface/power supply: 1.5 kV AC
Test voltage data interfaces: 1.5 kV AC
Supply
Supply voltage range: 18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block)
Nominal supply voltage: 24 V AC/DC
Typical current consumption: 85 mA (24VDC)
Max. current consumption: 100 mA
Connection dataSupply
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 24 ... 12
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesInterface: RS-232/-485
Bit distortion: ≤ 5 %
Bit delay: ≤ 2.5 µs
Signal: Modbus
Transmission channels: 2 (1/1), RxD, TxD, full duplex
Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN66259-1
Serial transmission speed: 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2kbps
Connection method: D-SUB9 plug
Pin assignment: DTE/DCE switchover via switch
Transmission length: 15 m (shielded twisted pair)
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 12
Min. AWG conductor cross section, flexible: 24
Protocols supported: transparent protocol
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Serial transmission speed: 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps
Connection method: Pluggable screw connection
Transmission length: 1200 m (shielded twisted pair)
Termination resistor: 390 Ω
150 Ω
390 Ω (Can be connected)
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 13
Min. AWG conductor cross section, flexible: 24
Protocols supported: transparent protocol
Data: RS-485 interface in acc. with EIA/TIA-485, DIN 66259-1
Serial transmission speed: 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps
Connection method: Pluggable screw connection
Transmission length: 1200 m (shielded twisted pair)
Termination resistor: 390 Ω
150 Ω
390 Ω (Can be connected)
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible: 14
Min. AWG conductor cross section, flexible: 24
Data direction switching: Automatic control or via RTS/CTS
Protocols supported: transparent protocol
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d5d8fb589b189545a32006c46a180100/-S204x204-FJPG
Width: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsMaterial: PA 6.6-FR
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
EAC
Identification: EAC
ATEX
Identification:  II 3 G Ex nA IIC T4 Gc
Certificate: IBExU16ATEXB004 X
Note: Please follow the special installation instructions in the documentation!
IECEx
Identification: Ex nA IIC T4 Gc
Certificate: IECEx IBE 15.0034X
UL, USA/Canada
Identification: 508 Recognized
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
KC approval for South Korea
Certificate: MSIP-REI-PCK-ME2744416
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
Identification: DNV GL
DNV GL data
Temperature: B
Humidity: A
Vibration: A
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV (Test Level 3)
Discharge in air: ± 8 kV (Test Level 3)
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 26 MHz ... 3 GHz (Test Level 3)
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2.2 kV (Test Level 3)
Signal: ± 2.2 kV (Test Level 3)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV (DC supply)
Signal: ± 1 kV (Data line, asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55011
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27242208
ECLASS-12.0: 27242208
ECLASS-13.0: 27242208
ETIMETIM 9.0: EC001423
UNSPSCUNSPSC 21.0: 32151700
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00160.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00121.pdf

Approvals_01271.pdf

Approvals_01307.pdf

Approvals_01308.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01763.pdf

Certification_00244.pdf

Certification_00259.pdf

Data_sheet_03430.pdf

Manufacturer_declaration_04662.pdf

Manufacturer_declaration_05543.pdf

Manufacturer_declaration_14856.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01860.pdf

Technical_drawing_38198.pdf