Product properties | Product type: Data cable by the meter Sensor type: Ethernet Number of positions: 4 |
Electrical properties | Nominal voltage UN: 48 VAC Transmission medium: Copper |
Interfaces | Signal type/category: Ethernet CAT5 (IEC 11801), 100 Mbps |
Cable/line | Cable length: Free entry (1.0 ... 1000.0 m) Ethernet[93E] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fd5ed9ddbd9ee4479cbb211f37ad0702/-S204x204-FJPG Cable weight: 43 kg/km Number of positions: 4 Shielded: yes Cable type: Ethernet[93E] Conductor structure: 2x2xAWG26/7, SF/UTP Signal runtime: 4.3 ns/m Signal speed: 0.77 c Conductor structure signal line: 7x 0.16 mm AWG signal line: 26 Conductor cross section: 2x 2x 0.14 mm² Wire diameter incl. insulation: 1 mm -0.2mm External cable diameter: 5.75 mm ±0.15mm Outer sheath, material: PUR External sheath, color: water blue RAL5021 Conductor material: Bare Cu litz wires Material wire insulation: Foam-Skin PE Single wire, color: white/orange-orange, white/green-green Twisted pairs: 2 cores to the pair Overall twist: Two pairs with two fillers to the core Optical shield covering: 85 % Max. conductor resistance: ⤠284 é/km Insulation resistance: ⥠5 Gé*km Coupling resistance: ⤠5.00 mé/m (at 20ÃHz) Wave impedance: 100 é ±15% (at 1 ... 100 MHz) Cable capacity: nom. 48 nF/km (At 800 Hz) Nominal voltage, cable: 50 Vrms 125 V (Peak value, not for high-power applications) Test voltage Core/Core: 1000 Vrms Test voltage Core/Shield: 500 Vrms Smallest bending radius, fixed installation: 30 mm (cable, fixed installation) Smallest bending radius, movable installation: 78 mm (Cable, flexible installation) Tensile strength: ⤠50 N (temporary) ⤠10 N (Permanent) Near end crosstalk attenuation (NEXT): 66 dB/m (with 1 MHz) 57 dB/m (at 4 ÃHz) 52 dB/m (at 10 MHz) 50 dB/m (at 16 MHz) 47 dB/m (at 20ÃHz) 45 dB/m (at 31.25ÃHz) 40 dB/m (at 62.5ÃHz) 36 dB/m (at 100 MHz) Crosstalk attenuation (ACR): 6.57 dB/m (with 1 MHz) 5.64 dB/m (at 4 ÃHz) 5.12 dB/m (at 10 MHz) 4.89 dB/m (at 16 MHz) 4.57 dB/m (at 20ÃHz) 4.34 dB/m (at 31.25ÃHz) 3.77 dB/m (at 62.5ÃHz) 3.31 dB/m (at 100 MHz) Shield attenuation: 0.028 dB/m (with 1 MHz) 0.06 dB/m (at 4 ÃHz) 0.085 dB/m (at 10 MHz) 0.115 dB/m (at 16 MHz) 0.128 dB/m (at 20ÃHz) 0.162 dB/m (at 31.25ÃHz) 0.23 dB/m (at 62.5ÃHz) 0.29 dB/m (at 100 MHz) Flame resistance: according to VDE0482 Part265-2-1 according to IEC 332-1 Ambient temperature (operation): -30°C ... 80°C (cable, fixed installation) Ambient temperature (installation): -5°C ... 60°C |
ECLASS | ECLASS-11.0: 27061801 ECLASS-12.0: 27061801 ECLASS-13.0: 27061801 |
ETIM | ETIM 9.0: EC003249 |
UNSPSC | UNSPSC 21.0: 26121600 |
Description other products