VAL-MS-T1/T2 335/12.5/1+1-FM - Lightning/surge arrester type 1/2
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | IEC test classification: I / II T1 / T2 EN type: T1 / T2 IEC power supply system: TT TN-S Type: DIN rail module, two-section, divisible Product type: Arrester combination Product family: VALVETRAB MS Number of positions: 2 Surge protection fault message: Optical, remote indicator contact Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal frequency fN: 50 Hz (60Hz) Indicator/remote signaling Connection name: Remote fault indicator contact Switching function: Changeover contact Operating voltage: 5 VAC ... 250 VAC 30 VDC Operating current: 5 mA AC ... 1.5 A AC 1 ADC |
Connection data | Connection method: Screw connection Fork-type cable lug Screw thread: M5 Tightening torque: 3 Nm (1.5mm² ... 16mm²) 4.5 Nm (25mm²...35mm²) Stripping length: 16 mm Conductor cross section flexible: 1.5 mm² ... 25 mm² 1.5 mm² ... 16 mm² Conductor cross section rigid: 1.5 mm² ... 35 mm² Conductor cross section AWG: 15 ... 2 Remote fault indicator contact Connection method: Plug-in/screw connection via COMBICON Screw thread: M2 Tightening torque: 0.25 Nm Stripping length: 7 mm Conductor cross section flexible: 0.14 mm² ... 1.5 mm² Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/92f303a1ff177b4b8889331526b3945f/-S204x204-FJPG Width: 35.6 mm Height: 96.8 mm Depth: 77.5 mm (incl. DIN rail 7.5mm) Horizontal pitch: 2 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6/PBT Material group: I Housing material: PA 6.6 PBT |
Mechanical properties | Mechanical data Open side panel: No |
Protective circuit | Mode of protection: L-N L-PE N-PE Direction of action: 1L-N & N-PE Nominal voltage UN: 240VAC (TN-S) 240VAC (TT) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous operating voltage UC (L-N): 335 VAC Maximum continuous operating voltage UC (L-PE): 335 VAC Maximum continuous operating voltage UC (N-PE): 264 VAC Rated load current IL: 80 A Residual current IPE: ⤠5 µA Standby power consumption PC: ⤠270 mVA Nominal discharge current In (8/20) µs (L-N): 12.5 kA Nominal discharge current In (8/20) µs (L-PE): 12.5 kA Nominal discharge current In (8/20) µs (N-PE): 50 kA Maximum discharge current Imax (8/20) µs: 50 kA Impulse discharge current (10/350)µs (L-N), charge: 6.25 As Impulse discharge current (10/350) µs (L-N), specific energy: 39 kJ/é Impulse discharge current (10/350)µs (L-N), peak current value Iimp: 12.5 kA Impulse discharge current (10/350) µs (L-PE), charge: 6.25 As Impulse discharge current (10/350)µs (L-PE), specific energy: 39 kJ/é Impulse discharge current (10/350) µs (L-PE), peak current value Iimp: 12.5 kA Impulse discharge current (10/350) µs (N-PE), charge: 25 As Impulse discharge current (10/350) µs (N-PE), specific energy: 625 kJ/é Impulse discharge current (10/350) µs (N-PE), peak current value Iimp: 50 kA Total discharge current Itotal (8/20)µs: 50 kA Total discharge current Itotal (10/350)µs: 25 kA Follow current interrupt rating Ifi (N-PE): 100 A Short-circuit current rating ISCCR: 25 kA Voltage protection level Up (L-N): ⤠1.2 kV ⤠1.6 kV (30 kA - 8/20 µs) Voltage protection level Up (L-PE): ⤠2 kV Voltage protection level Up (N-PE): ⤠1.7 kV Residual voltage Ures (L-N): ⤠1.2 kV (at In) ⤠1.1 kV (at 10 kA) ⤠1 kV (at 5 kA) ⤠0.9 kV (at 3kA) Residual voltage Ures (L-PE): ⤠2 kV (at In) ⤠1.5 kV (at 10 kA) ⤠1.2 kV (at 5 kA) ⤠1.1 kV (at 3kA) Residual voltage Ures (N-PE): ⤠0.6 kV (at In) ⤠0.5 kV (at 10 kA) ⤠0.5 kV (at 5 kA) ⤠0.4 kV (at 3kA) TOV behavior at UT (L-N): 415 VAC (5s / withstand mode) 457 VAC (120min / safe failure mode) TOV behavior at UT (N-PE): 1200 VAC (200ms / withstand mode) Response time tA (L-N): ⤠25 ns Response time tA (L-PE): ⤠100 ns Response time tA (N-PE): ⤠100 ns Max. backup fuse with V-type through wiring: 80 A (gG - 16 mm²) Max. backup fuse with branch wiring: 160 A (gG) Additional technical data Maximum discharge current Imax (8/20) µs: 65 kA |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (only when all terminal points are used) Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
Approvals | UL specifications Maximum continuous operating voltage MCOV (L-N): 335 VAC Maximum continuous operating voltage MCOV (L-G): 335 VAC Maximum continuous operating voltage MCOV (N-G): 264 VAC Nominal discharge current In (L-N): 20 kA Nominal discharge current In (L-G): 20 kA Nominal discharge current In (N-G): 20 kA Mode of protection: L-N L-G N-G Nominal voltage: 240VAC Power distribution system: Single phase Nominal frequency: 50/60 Hz Measured limiting voltage MLV (L-N): 2630 V Measured limiting voltage MLV (L-G): 3600 V Measured limiting voltage MLV (N-G): 2600 V SPD Type: 4CA UL indicator/remote signaling Operating voltage: 125 VAC AC operating current: 1 A AC UL connection data Tightening torque: 30 lbf-in. Conductor cross section AWG: 14 ... 2 |
Standards and regulations | Standards/specifications: IEC 61643-11 Note: 2011 EN 61643-11 Standards/specifications: EN61643-11 Note: 2012 |
Mounting | Mounting type: DIN rail: 35 mm |
ECLASS | ECLASS-11.0: 27130802 ECLASS-13.0: 27171201 |
ETIM | ETIM 9.0: EC000381 |
UNSPSC | UNSPSC 21.0: 39121600 |