VAL-MS 75 VF ST - Type 2 surge protection plug

Surge protection plug type 2 with series connection consisting of varistor and gas-filled spark gap for VAL-MS base element, thermal monitoring, visual fault warning.
Product Code: 2805318
Partner cod.: 2805318
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesGeneral
Note: The values specified for the L-L protective path are only valid in connection with VAL-MS/2+0-BE/FM/S2
Product propertiesIEC test classification: II
T2
EN type: T2
Type: DIN rail module, two-section, divisible
Product type: Replacement plug
Product family: VALVETRAB MS
Number of positions: 1
Surge protection fault message: optical
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Nominal voltage UN: 5 VAC ... 48 VAC
Connection dataConnection method: pluggable
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3e02d9b64ee0a341a2e312513f1ad825/-S204x204-FJPG
Width: 17.5 mm
Height: 52.4 mm
Depth: 55.3 mm
Horizontal pitch: 1 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA 6.6
Material group: I
Housing material: PA 6.6
Protective circuitMode of protection: L-PE
L-L
Direction of action: 1L-N/PE
Nominal voltage UN: 5 VAC ... 48 VAC
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 75 VAC
100 VDC
Residual current IPE: ≤ 5 µA
Standby power consumption PC: ≤ 1 mVA
Nominal discharge current In (8/20) µs: 10 kA
Maximum discharge current Imax (8/20) µs: 20 kA
Short-circuit current rating ISCCR: 10 kA
Voltage protection level Up: ≤ 1.4 kV
Voltage protection level Up (L-L): ≤ 1.8 kV
Residual voltage Ures: ≤ 0.45 kV (at In)
≤ 0.35 kV (at 5 kA)
≤ 0.3 kV (at 3kA)
Residual voltage Ures (L-L): ≤ 0.9 kV (at In)
≤ 0.7 kV (at 5 kA)
≤ 0.6 kV (at 3kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs: ≤ 1.4 kV
Response time tA: ≤ 100 ns
Max. backup fuse with branch wiring: 63 A (gG)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g
Vibration (operation): 5g
ApprovalsUL specifications
Maximum continuous operating voltage MCOV (L-N): 75 VAC
Maximum continuous operating voltage MCOV (L+) - (L-): 100 VDC
Nominal discharge current In (L-N): 10 kA
Nominal discharge current In (L+) - (L-): 10 kA
Mode of protection: L-N
(L+) - (L-)
Nominal voltage: 48VAC
60 VDC
Power distribution system: Single phase
Nominal frequency: 50/60 Hz
Measured limiting voltage MLV (L-N): 1760 V
Measured limiting voltage MLV (L+) - (L-): 1760 V
SPD Type: 4CA
Standards and regulationsStandards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: on base element
Technical Specs
ECLASSECLASS-11.0: 27130890
ECLASS-13.0: 27171292
ETIMETIM 9.0: EC002496
UNSPSCUNSPSC 21.0: 39121600
Description
Surge protection plug type 2 with series connection consisting of varistor and gas-filled spark gap for VAL-MS base element, thermal monitoring, visual fault warning.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Approvals_00980.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Manufacturer_declaration_00772.pdf

Manufacturer_declaration_02300.pdf

Package_slip_00514.pdf

Product_information_00033.pdf

Technical_drawing_38585.pdf