PHOENIX CONTACT 2819765
PHOENIX CONTACT 2819765
PHOENIX CONTACTNot available

IB IL INC-IN-2MBD-PAC - Special function module

Inline, Position detection module, Incremental encoder input:1, Symmetrical and asymmetrical encoders, Digital inputs:3, 24 VDC, Digital outputs:1, 0.5 A, transmission speed in the local bus:2 Mbps, degree of protection:IP20, including Inline connectors and marking fields
Product Code: 2819765
Partner cod.: 2819765
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/63a4d567f575814996d04defd50b4eeb/-S204x204-FJPG
Width: 24.4 mm
Height: 140.5 mm
Depth: 71.5 mm
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesInline local bus
Number of interfaces: 2
Connection method: Inline data jumper
Transmission speed: 2 Mbps
Transmission physics: Copper
System propertiesModule
ID code (dec.): 127
ID code (hex): 7F
Length code (hex): 02
Length code (dec): 02
Process data channel: 32 bit
Input address area: 4 Byte
Output address area: 4 Byte
Register length: 4 Byte
Required parameter data: 1 Byte
Required configuration data: 5 Byte
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2 type 1
Number of inputs: 3
Connection method: Spring-cage connection
Connection technology: 3-conductor
Input voltage range "0" signal: -3 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 15 VÂDC ... 30 VÂDC
Nominal input voltage UIN: 24 VÂDC
Nominal input current at UIN: typ. 2.7 mA
Encoder
Number of inputs: 1 (Symmetrical or asymmetrical)
Input name: Incremental encoder input
Encoder signals: Symmetrical and asymmetrical encoders
Cable length: max. 30 m (shielded cable, to ensure conformance with EMC Directive)
Output dataDigital
Output name: Digital outputs
Connection method: Spring-cage connection
Connection technology: 2-conductor
Number of outputs: 1 (NPN, double assignment of input E3)
Product propertiesType: modular
Product type: I/O component
Product family: Inline
Scope of delivery: including Inline connectors and marking fields
Operating mode: Process data mode with two words
Insulation characteristics
Overvoltage category: II (IEC 60664-1, ENÂ60664-1)
Pollution degree: 2 (IEC 60664-1, ENÂ60664-1)
Electrical propertiesEncoder
Number: 1
max. 1 (A, /A, B, /B, Z, /Z)
max. 1 (A, B, (Z))
Nominal output voltage: 5 VÂDC
24 VÂDC
Voltage range: 4.75 VÂDC ... 5.25 VÂDC
19.2 VÂDC ... 30 VÂDC
Current carrying capacity: max. 250 mA
Protective circuit: Short-circuit protection; Electrical and thermal
Short-circuit protection; Electronic and thermal
Designation: Symmetrical incremental encoders
Asymmetrical incremental encoder
Encoder supply voltage: 5 VÂDC
24 VÂDC
5 VÂDC
24 VÂDC
Signal voltage level: Differential signal (signal âۉ€œ inverted signal)±0.5ÂV, minimum; ±6ÂV, maximum
Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Common mode voltage range signal - ground: -10 VÂDC ... 13.2 VÂDC
Input frequency: max. 300 kHz
Potentials: Communications power (U
Supply voltage: 7.5 V (via voltage jumper)
Current draw: max. 80 mA
Power consumption: max. 600 mW
Potentials: Main circuit supply (U
Supply voltage: 24 VÂDC (via voltage jumper)
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 1 A
typ. 340 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O): 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24ÂV supply (I/O) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 7.5ÂV supply (bus logic)/functional ground: 500 VÂAC, 50 Hz, 500 min.
Connection dataConnection technology
Connection name: Inline connector
Conductor connection
Connection method: Spring-cage connection
Conductor cross section rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Inline connector
Connection method: Spring-cage connection
Conductor cross section, rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 55°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 10 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
MountingMounting type: DIN rail mounting
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00104.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Data_sheet_03470.pdf

Manual_00085.pdf

Manufacturer_declaration_00909.pdf

Manufacturer_declaration_01766.pdf

Manufacturer_declaration_05564.pdf

Package_slip_01373.pdf

Various_00038.pdf